13. S-AIR TEST MODE (KS360S only)
Procedure:
1. Enter the test mode menu.
2. Press the [↑]/[↓] buttons to select "SAIR TST", and press the
[ENTER] button.
3. S-AIR test menu is displayed.
4. Press the [
] button to exit from the test mode.
?/1
13-1. Power
Procedure:
1. Enter the S-AIR test mode.
2. Press the [↑]/[↓] buttons to select "POWER", and press the
[ENTER] button.
3. The messages "000 SET" is appears.
4. Press the [↑]/[↓] buttons to select the output power. (OFF or
000 to 063)
5. Press the [ENTER] button, return to S-AIR test mode each
item.
13-2. NAMG
Procedure:
1. Enter the S-AIR test mode.
2. Press the [↑]/[↓] buttons to select "NAMG", and press the
[ENTER] button.
3. The messages "116 SET" is appears.
4. Press the [↑]/[↓] buttons to select the NAMG setting value.
(107 to 117)
5. Press the [ENTER] button, return to S-AIR test mode each
item.
13-3. Version check
T E
L
1 3 9 4 2 2 9 6 5 1 3
Procedure:
1. Enter the S-AIR test mode.
2. Press the [↑]/[↓] buttons to select "VER. CHECK", and press
the [ENTER] button.
3. uCom software version of S-AIR product is displayed.
4. Press the [ENTER] button, return to S-AIR test mode each
item.
13-4. Encryption key
Procedure:
1. Enter the S-AIR test mode.
2. Press the [↑]/[↓] buttons to select "ENC KEY", and press the
[ENTER] button.
3. The on/off setting of the encryption key is displayed.
4. Press the [↑]/[↓] buttons to select the encryption key setting.
(ON or OFF)
5. Press the [ENTER] button, return to S-AIR test mode each
item.
14. S-AIR TEST ELEC MODE
Not used for the servicing.
Press the [
] button if having entered this mode.
?/1
15. UART FLASH (SOURCE)
Not used for the servicing.
Press the [
] button if having entered this mode.
?/1
16. UART FLASH (TARGET)
Not used for the servicing.
w w w
Press the [
] button if having entered this mode.
?/1
STR-KS360/KS360S
17. COLD RESET
Procedure:
1. Enter the test mode menu.
2. Press the [↑]/[↓] buttons to select "COLD RST", and press the
[ENTER] button.
3. The message "CLEARED" appears, then the set turns off.
x
a o
y
.
i
http://www.xiaoyu163.com
8
FM AUTO STOP CHECK
signal
generator
set
Procedure:
1. Turn on the set.
2. Input the following signal from signal generator to FM antenna
input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation
: 75 kHz
Modulation
: 1 kHz
ANT input
: 35 dBu (EMF)
Note: Use 75 ohm coaxial cable to connect signal generator and the set.
You cannot use video cable for checking.
Use signal generator whose output impedance is 75 ohm.
3. Set to FM tuner function and scan the input FM signal with
automatic scanning.
4. Confi rm that input frequency of A, B and C are detected and
automatic scanning stops.
When the station signal is received in good condition, automatic
scanning stops.
Q
Q
3
7
6
3
u 1 6 3
.
11
11
SECTION 5

ELECTRICAL CHECK

2
4
9
9
8
1
5
1
5
0
8
9
2
4
m
c o
STR-KS360/KS360S
2
9
9
9
8
2
9
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Str-ks360

Table of Contents