MODEL:
NP6251
Major quality issues
Field quality problems
LOCATION:
SUBJECT:
Outline
Notification is made here of how to perform adjustment if for the reason of problem with the lens a lens
stage has been replaced, and then after this replacement the lens fails to yield good resolution.
Lens stage replacement procedure (refer to the Service Manual)
1) Disconnect the plug and remove the copyboard glass and lens hood.
2) Move the mirror 1 mount to the right and remove the stage wire fixture (1 in Figure 1; 2 locations).
3) Remove the lens stage cable (2 in Figure 1, Figure 2 enlargement; connector, ground wire).
After replacing the lens stage, attach the cable following the same path as before so that the movement of
the lens stage is not affected.)
4) Move the mirror 1 mount to the left direction.
5) Remove the light blocking curtain (3 in Figure 1; 2 locations)
The light blocking curtain is pasted to the lens with two-sided tape; be careful when peeling off the light
blocking curtain so as to avoid tearing it (enlarged Figure 3). After replacing the lens stage, re-attach it
with a two-sided tape.
6) Remove the sheet guide (1) (4 in Figure 1).
Sheet guide (1) is also attached to the new lens stage but since the light blocking sheet needs to be pasted
again, it is advisable to reuse the removed sheet guide.
7) Lift the left side of the lens stage and remove the bushing (5 in Figure 1) from the rail (2 locations).
8) After replacing the lens stage with a new one, attach the removed parts.
Mirror mount 1
2
1
5
SERVICE BULLETIN
Issued by Canon Europa N.V.
Quality upgrade/production efficiency
Miscellaneous
LENS MOUNT
ADJUSTING IMAGE AFTER REPLACING THE LENS STAGE
Fig. 1 Lens mount
COPIER
No.:
6251-001
(H2-12E-036)
DATE: 30.01.98
3
4
- 1/4 -