NOTE:
Double width GPUs are supported only on riser configuration 4, and single width GPUs are supported only on riser
configuration 6.
NOTE:
Ensure that x16 cards are installed only in x16 slots. Depending on the riser configuration slots 2, 7, or 8 may not be
available.
NOTE:
Only half length PCIe cards are supported on riser 2 when NVDIMM-Ns with NVDIMM-N battery are installed on the air
shroud.
NOTE:
For configurations that support GPU, maximum four single-wide and two double-wide GPUs are supported when
NVDIMM-Ns with NVDIMM-N battery are installed. Since NVDIMM-N battery is installed on the GPU shroud, GPUs are not
supported on riser 2.

Opening and closing the PCIe card holder latch

Before installing or removing a full length PCIe card, the PCIe card holder latch must be closed. When the full length PCIe card is installed,
open the PCIe card holder latch.
Prerequisites
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Steps
1
To open the PCIe card holder latch, press the release tab.
Figure 51. Opening the PCIe card holder latch
2
To close the PCIe card holder latch, push the latch until it locks.
106
Dell EMC PowerEdge R740 Installation and Service Manual
Installing and removing system components
Safety
instructions.