Sony MVS-6530 Installation Manual

Sony MVS-6530 Installation Manual

2m/e, 3m/e multi format switcher processor
Hide thumbs Also See for MVS-6530:

Advertisement

2M/E MULTI FORMAT SWITCHER PROCESSOR
MVS-6520
MVS-3000
3M/E MULTI FORMAT SWITCHER PROCESSOR
MVS-6530
FORMAT CONVERTER BOARD
MKS-6550
DIGITAL MULTI EFFECT BOARD
MKS-6570
INSTALLATION MANUAL
1st Edition

Advertisement

Table of Contents
loading

Summary of Contents for Sony MVS-6530

  • Page 1 2M/E MULTI FORMAT SWITCHER PROCESSOR MVS-6520 MVS-3000 3M/E MULTI FORMAT SWITCHER PROCESSOR MVS-6530 FORMAT CONVERTER BOARD MKS-6550 DIGITAL MULTI EFFECT BOARD MKS-6570 INSTALLATION MANUAL 1st Edition...
  • Page 2 ! 警告 このマニュアルは,サービス専用です。 お客様が,このマニュアルに記載された設置や保守,点検,修理などを行うと感電や火災, 人身事故につながることがあります。 危険をさけるため,サービストレーニングを受けた技術者のみご使用ください。 ! WARNING This manual is intended for qualifi ed service personnel only. To reduce the risk of electric shock, fi re or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualifi ed to do so. Refer all servicing to qualifi...
  • Page 3: Table Of Contents

    Table of Contents Manual Structure Purpose of this manual ............2 (E) Related manuals ..............2 (E) Trademarks ................2 (E) 1. Installation 1-1. Operating Environment ..........1-1 (E) 1-2. Power Supply ............1-1 (E) 1-2-1. Power Specifications........1-1 (E) 1-2-2. Power Cord ............1-1 (E) 1-3.
  • Page 4: Manual Structure

    This manual is the Installation Manual of following models. . 2M/E Multi Format Switcher Processor MVS-6520/3000 . 3M/E Multi Format Switcher Processor MVS-6530 This manual is intended for use by trained system and service engineers, and provides the information that is required to install (operating environment, installation space, connection information, etc.).
  • Page 5: Installation

    If you have questions on the use of the above Power Cord/ (Refer to the air flow illustration of “Fan” in Section Appliance Connector/Plug, please contact your local Sony 2-2-2.) Sales Office/Service Center. The power supply can be damaged if the exhaust vent (both sides) and air intake (front panel) are blocked or the fan is .
  • Page 6: Installation Space (External Dimensions)

    1-3. Installation Space (External Dimensions) MVS-6520 Φ26 53.5 115.5 115.5 60.5 Unit: mm 1-2 (E) MVS-6520...
  • Page 7 MVS-6530 Φ26 53.5 115.5 115.5 60.5 Unit: mm 1-3 (E) MVS-6520...
  • Page 8 MVS-3000 Φ26 53.5 115.5 115.5 60.5 Unit: mm 1-4 (E) MVS-6520...
  • Page 9: Installing The Optional Board

    1-4. Installing the Optional Board Installation Procedure 1. Turn off the main power of this unit and disconnect the The following options are available for the MVS-6520/6530/3000. AC power cord from the wall outlet. 2. Loosen the four screws (with drop-safe) and remove MVS-6520/6530 optional board list the front panel in the direction of the arrow.
  • Page 10 4. While the eject levers are opened as shown in the 5. While closing the eject levers in the direction of arrow illustration, insert the plug-in board into the board 1, push in the plug-in board. guide rail. 6. Attach the extract PWB stopper assembly and the front panel by reversing the installation steps of 2 and 3.
  • Page 11: Rack Mounting

    1-5. Rack Mounting 2. Rack mounting procedure This section describes the rack mounting procedure using The MVS-6520/6530/3000 is mounted in the 19-inch the RMM-10 rack mount kit. standard rack. To mount the MVS-6520/6530/3000 in the rack, use the specified rack mount kit and follow the 1.
  • Page 12 5. Tighten the screws (B4 x 6 : two screws each on the 3. Loosen the screws on the rear of the right and left adapters and adjust the length of the adapter according right and left) for adjusting the length of the adapter to the depth of the rack.
  • Page 13: Matching Connectors And Cables

    MVS-6520 OUT 1-16 (MVS-6520/3000) Belden 1694 coaxial /6530 OUT 1-16, 17-32 (MVS-6530) cable /3000 IN 1-16, 17-32 (MVS-6520/3000) IN 1-16, 17-32, 33-48 (MVS-6530) S-BUS REF IN REMOTE 1-4 D-sub 9-pin, D-sub 9-pin, male REMOTE S1, S2 Female Connector 9-pin, male...
  • Page 14: Input/Output Signals Of Connectors

    1-7. Input/Output Signals of Connectors REMOTE S1, S2: RS-422A (D-sub 9-pin, female) <DEVICE> (*2) from External Devices Input and output signals of the connectors on the rear panel are as follows. (External View) <DEVICE> indicates a controlled device. Pin No. Signal Name Function GPI: (D-sub 25-pin, female)
  • Page 15 FM DEVICE: USB Type A (4-pin) REMOTE1 to 4: RS-422A (D-sub 9-pin, female) <CONTROLLER> to External Device (External View) (External View) Pin No. Signal Name Function Pin No. Signal Name Function VBUS USB Vcc USB_ Frame ground USB+ Received data (_) Ground Transmitted data (+) Common ground...
  • Page 16: Description Of On-Board Switches, Leds And Connectors

    1-8. Description of On-board Switches, LEDs and Connectors 1-8-1. MVS-6520/6530/3000 The number shown in the parentheses ( ) indicated the address on the circuit board. CA-85 board D4101 D4102 D4103 S2601 S4101 S2602 S3501 D2601 D412 D201 D402 D403 D405 D401 D407 S3701...
  • Page 17 D412 (C-1): VTT-SCU D201 (C-2): +12V VTT-SCU power status indication. +12V power status indication. Lit when VTT-SCU is supplied. Lit when +12V is supplied. If this LED is not lit, the fuse may be blown. D501 (H-1): SWER_RST System reset status indication. D401 (D-2): +1.2V-1 Lit in the following cases.
  • Page 18 D2601 (C-1): SCU RESET Switch SCU CPU reset status indication. S501 (H-1): CA_RESET switch . When S2601 is pressed. Performs a reset of the CA-85 board alone. . When Reset is requested from software. . When IC4 does not start normally. S502 (H-1): RESET switch Performs a reset of whole MVS processor and restarts it.
  • Page 19 S3802 (D-1): SCU DBG SW switch D13 (A-4): GbE2 Not used. Lit when Ethernet 2 on the CPU-DP module is linked. Not used in the CA-85 board. S4101 (B-1): SW switch For the operation mode setting of SCU NIOS (IC5). D14 (A-4): SGMII1 Factory setting: OFF (all) Lit when SGMII 1 on the CPU-DP module is linked.
  • Page 20 MIX-55 board D302 D304 D308 D305 D306 D310 D303 D307 D309 D700 D1000-D1004 D2200-2207 D2208-2215 D2300-2307 D2308-2315 CN1101 CN1100 D600 S600 MIX-55 board (Side A) 1-16 (E) MVS-6520...
  • Page 21 D2200 to D2207 (F-1): IMP1 (PP_K12) status LED D302 (C-1): +12V IMP1 status indication. +12V power status indication. Lit when +12V is supplied. D2208 to D2215 (F-1): IMP2 (PP_K34) status LED IMP2 status indication. D304 (C-1): +3.3V +3.3V power status indication. D2300 to D2307 (G-1): IMP3 (ME1_K12) status LED IMP3 status indication.
  • Page 22 MY-119 board D203 D406 D404 D402 D401 D403 D405 D1301 D1303 D1201 D1304 to D1319 (7SEG LED) CPU-DP D702 D705 module D701 D704 D902 D703 D901 S501 S601 MY-119 board (Side A) 1-18 (E) MVS-6520...
  • Page 23 D702 (G-1): INET ACT D203 (C-1): +12V Blinks in green during data transmission/reception when +12V power status indication. Ethernet1 on CPU (CPU-DP module) is linked with the Lit in green when +12V is supplied. CA-85 board. D404 (C-1): +5V (SSD) D701 (G-1): INET LINK +5V power (for SSD) status indication.
  • Page 24 XPT-34 board D003 D202 D203 D204 D201 D205 D206 D701 D702 D703 D704 D501 D401 XPT-34 board (Side A) 1-20 (E) MVS-6520...
  • Page 25 D704 (D-1): OUT2 D003 (C-1): +12V Status indication of IC004 FPGA configuration operation. +12V power status indication. Goes out when the configuration of IC004 is completed. Lit when +12V is supplied. If it does not go out, there may be a defect in IC004. D202 (C-1): +3.3V D501 (D-1): CADEC +3.3V power status indication.
  • Page 26: Dvp-55 Board (Mks-6570)

    1-8-2. DVP-55 Board (MKS-6570) The number shown in the parentheses ( ) indicated the address on the circuit board. D203 D302 D304 D305 D301 D909 D306 D307 D303 D601 D1102 D1101 D901 to D908 DVP-55 board (Side A) 1-22 (E) MVS-6520...
  • Page 27 D1101 (E-1): PVFLT D203 (C-1): +12V FPGA configuration error indication. +12V power status indication. When this LED is lit, FPGA (IC2) may not operate nor- Lit when +12V is supplied. mally. D302 (C-1): +3.3V D909 (D-2): PPC_RST +3.3V power status indication. Power PC reset indication.
  • Page 28: Fc-114 Board (Mks-6550)

    1-8-3. FC-114 Board (MKS-6550) The number shown in the parentheses ( ) indicated the address on the circuit board. D003 D202 D203 D204 D201 D206 D905 D904 D903 D902 D901 FC-114 board (Side A) 1-24 (E) MVS-6520...
  • Page 29 D003 (D-1): +12V +12V power status indication. Lit when +12V is supplied. D202 (D-1): +3.3V +3.3V power status indication. Lit when +3.3V is supplied. D203 (D-1): +2.5V +2.5V power status indication. Lit when +2.5V is supplied. D204 (D-1): +1.8V +1.8V power status indication. Lit when +1.8V is supplied.
  • Page 30: System Connection

    Terminate with the supplied 75 Z terminators. LAN cable (straight type) Terminators are supplied in the product package. Cable with BNC connectors b) The figure shows the MVS-6530. c) The figure shows the ICP-6530. DVI cable USB cable 1-26 (E)
  • Page 31: Connection Example Of The Mvs-3000 System

    1-9-2. Connection Example of the MVS-3000 System ICP-3000 Control Panel Camera Playback VTR CG video/key signal generator, etc. DVI-D AC power supplies IN 1 to 32 MVS-3000 Multi Format Switcher OUT 1 to 16 AC power supplies DEVICE Reference video signal Menu display monitor Video output monitor (program output, preview, multi viewer, etc.) Removable disk...
  • Page 33: Service Overview

    Section 2 Service Overview 2-1. Troubleshooting Power of MVS-6520/6530/3000 does not turn on Monitor image is not output correctly (LED is not lit in green.) Power of MVS-6520/6530/ Power of MVS-6520/6530/ 3000 is turned on, but the 3000 does not turn on. image is not output to the (LED is not lit in green.) monitor correctly.
  • Page 34: Cleaning

    This may have an adverse effect on performance and the life of the machine. Cleaning of the fan every month is recommended. Contact your local Sony Sales Office/Service Center for information on cleaning the fan. Air flow 1 Fan motor 120 square (for plug-in board)
  • Page 35: About The Data Backup Capacitor

    2-3. About the Data Backup Capacitor A large capacitor is installed on the CA-85 board in order to retain the data such as the resume data, snapshots, and effects in the MVS-6520/6530/3000 machine. Leave the main power of the MVS-6520/6530/3000 turned on for two hours or longer in order to charge this capacitor.
  • Page 38 MVS-6520 (SY) MVS-6530 (SY) Printed in Japan Sony Corporation MVS-3000 (SY) J, E 2012. 9 08 4-446-372-01 ©2012...