Line differential protection and control (36 pages)
Summary of Contents for ABB RHD8000
Page 1
— RHD8000 RHD16000 Compact actuator for the operation of final control Additional documentation on RHD8000 / RHD16000 elements with preferably 90° rotary movement such (Contrac) is available for download free of charge at as valve flaps, ball valves, etc. www.abb.com/actuators.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Table of contents Change from one to two columns Commissioning ............24 Safety ................3 General information and instructions ........3 Operation ..............24 ...
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Change from one to two columns 1 Safety Warnings General information and instructions The warnings in these instructions are structured as follows: These instructions are an important part of the product and must be retained for future reference.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Intended use Warranty provisions Control actuators are used exclusively for operating final control Using the device in a manner that does not fall within the scope elements (valves, valve flaps, etc.).
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 3 Product identification 4 Transport and storage Name plate Inspection Check the devices immediately after unpacking for possible Antrieb/ Actuator: CONTRAC ..damage that may have occurred from improper transport.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 5 Installation Storing the device Safety instructions Note DANGER The storage data provided below assumes that the devices are Danger to life due to falling or toppling loads. fully closed and thus comply with the IP rating stated in the Risk of death or serious injury due to the device falling down specification.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D … 5 Installation … Mounting Mounting position Installation instructions The spur gear of the actuator RHD8000 / RHD16000 (Contrac) • Make sure that no process forces are exerted on the final are lubricated with oil.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Travel-dependent stop adjustment Assembly with the final control element 1. Remove the lever cover. WARNING 2. Move the actuator lever / final control element to the end position requiring finer mechanical adjustment.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D … 5 Installation … Mounting Installation variants Mounting with lever Locking and fastening elements Locking screws of mechanical limit stops Tightening torque Nm (lbf-ft) 670 (494.17) lever clamping screw Tightening torque Nm (lbf-ft) 1400 (1032.56)
Page 13
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Installation with additional output elements Configuring the drive element hub When mounting an additional drive element instead of the The new output element is mechanically connected to the standard lever, the following installation conditions must be actuator shaft via a hole with feather key groove.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 6 Electrical connections Conductor cross-section on electronic unit Safety instructions Note WARNING Detailed information on separate electronic units can be found Risk of injury due to live parts! in the corresponding data sheets.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Cable glands The actuators and electronic units are supplied without cable glands. Suited cable glands must be installed on site. Tap holes for cable glands metric optional adapters for* Signals M20 ×...
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D … 6 Electrical connections Electronic unit EBS853 (Contrac) / EBS861 (Contrac) Analog / Digital Note The electrical connection is provided by a universal plug on the actuator and the screw terminals on the electronic unit.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D PROFIBUS DP® Note The electrical connection is provided by a universal plug on the actuator and the screw terminals on the electronic unit. 115 V Sub distribution board 230 V AC...
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D … 6 Electrical connections Electronic Unit EBN852 (Contrac) Analog / Digital Note • The electrical connection is provided by a universal plug on the actuator and the screw terminals on the electronic unit.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Electronic Unit EBN862 (Contrac) Analog / Digital Note The electrical connection is provided by a universal plug on the actuator and the screw terminals on the electronic unit. 115 V...
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 7 Commissioning Automatic mode / Handwheel mode Note It is imperative that you observe the operating instruction of the WARNING corresponding electronic unit for the commissioning of the actuator.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Handwheel operation in combination with positioning loop monitoring The positioning loop monitoring of the electronic unit monitors actuator behavior. It monitors whether the travel commands trigger the corresponding processes.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 9 Diagnosis / error messages This chapter only covers hardware-related errors. For additional troubleshooting information, refer to the online help for the operator interface. Error Possible cause Troubleshooting the Instrument Valve cannot be moved by actuator.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 10 Maintenance General Safety instructions Contrac actuators feature a robust construction. As a result, WARNING they are highly reliable and require minimal maintenance. The Risk of injury due to live parts!
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D … 10 Maintenance Removing the motor and adjusting the Oil change brakes Note Oils for different temperature ranges may not mixed. WARNING During an oil change, thoroughly remove any oil that may have Risk of injury! escaped to avoid accidents.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 11 Repair 12 Recycling and disposal Repair and maintenance activities may only be performed by Note authorized customer service personnel. Products that are marked with the adjacent symbol When replacing or repairing individual components, use original may not be disposed of as unsorted municipal waste spare parts.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 13 Approvals and certifications CE mark The version of the device as provided by us meets the requirements of the following EU directives: • EMC directive 2014/30/EU • Machinery Directive 2006/42/EC / 2006/42/EG •...
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D 15 Appendix Return form Statement on the contamination of devices and components Repair and/or maintenance work will only be performed on devices and components if a statement form has been completed and submitted.
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D … 15 Appendix Installation declaration Change from one to two columns...
Page 33
RHD8000 / RHD16000 (Contrac) ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D Trademarks HART is a registered trademark of FieldComm Group, Austin, Texas, USA PROFIBUS and PROFIBUS DP are registered trademarks of PROFIBUS & PROFINET International (PI)
Page 36
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.