Xerox N24/32/40 Technical Instructions Step 4 Using a Philips screwdriver remove the Photo 6 Photo 5 two screws holding the drum axle hub on the contact side of the waste hopper. (See Photo 5). Remove the drum axle hub. (See Photo 6)
Xerox N24/32/40 Technical Instructions Photo 15 Step 10 Step 10: Dump out the waste toner from the hopper. Using dry com- Step 15 pressed air or a vacuum clean out the Using a cotton swab and alcohol waste hopper. clean the PCR contact cradle.
Xerox N24/32/40 Technical Instructions Photo 24 Step 19 Remove the screw that holds the mag roller end cap on the gear end of the Step 17 mag roller. (See Photo 24) Remove the Install the drum axle hubs on end cap.
Xerox N24/32/40 Technical Instructions Photo 29 Step 25 Remove the four screws found along the top of the toner hopper. (See Photo 29) Step 30 Using dry compressed air or a vacuum clean out the toner hopper and the toner hopper cover.
Xerox N24/32/40 Technical Instructions Photo 38 Step 34 Using needle nose pliers grab the metal toner agitator bar and pull it from the Step 32 agitator gear. (See Photo 38) Release the four clips (two on the top and two on the bottom) that hold the contact end cap to the hopper.
Xerox N24/32/40 Technical Instructions Photo 43 Step 39 With the seal pull tab through the seal exit port, use needle nose pliers to hold Step 44 the agitator bar in the correct position while reinstalling the seal exit port plug.
Xerox N24/32/40 Technical Instructions Photo 50 Step 48 Step 46 Replace or reset the cartridge Grab the waste hopper by the handle chip, check with your supplier and lower the waste hopper onto the for your best option. toner hopper. Once the two sections...
Xerox cartridges do not. If the cartridge is tilted on its end after the seal is pulled toner will leak out from the Problem #2: ends of the mag roller.