COPIER > OPTION > USER
CNT-SW
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
BCNT-AST
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
PRJOB-CP
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Supplement/Memo
DOC-REM
1
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
DPT-ID-7
2
Detail
Use Case
Adj/Set/Operate Method
Display/Adj/Set Range
Default Value
Set default dspl items on charge counter
To set default display items of the charge counter on the Counter Check screen.
For details of each type, refer to the Service Manual.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Type1 , 1: Type2
0
Set of box print charge target job
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set the job type that advances the count in box print with NE Controller (ASSIST).
When switching the job type that is subject to counting of the box print with NE Controller
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: PDL job, 1: Copy job
0
Set count TX at RX/report print
To set to enable/disable a page-basis count pulse transmission to the charging management
device at the time of reception print or report print.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: No transmission, 1: Transmission
0
Charging management device: Coin Manager, Non-Canon-made control card
Display/hide of original removal message
To set whether to display or hide the message to remove original when scanning with DADF without
opening/closing DADF after scanning with the Copyboard.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Hide, 1: Display
0
Password entry set at dept ID reg/auth
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set whether to require a password entry at the time of registration/authentication of department
ID.
With the setting to require entry, entry of 7-digit password is required as well as entry of department
ID.
Upon user's request
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
0 to 1
0: Department ID only, 1: 7-digit (password) entry
0
776