Page 1
5051 3513 5052 6211 5050 3511 3510 3321 5060 5061 3310 5062 3010 6210 R R Date/T Date/Tarih arih Rev No Rev No Main Body Main Body 3322 Gövde Grubu Gövde Grubu 3320 1799841888...
Page 4
2411 2414 2413 7262 7266 7264 7221 7265 7263 7261 7220 2427 7260 2424 2423 2425 2426 2420 7211 2421 9102 7611 7640 2433 7630 2430 7620 7610 R Date/Tarih 9935 Su sistemi Inner tub 17 9982 1720...
Page 5
DFN2520S REPERE REFERENCE DESIGNATION 1881810100 SUPPORT PIED GAUCHE 1881810200 SUPPORT PIED DROIT 1881790100 SUPPORT DE PIED 1880080392 SOCLE 1883140100 PIED AJUSTABLE 1880111310 PANNEAU GAUCHE 1880111410 PANNEAU DROIT 1880012000 SUPPORT CONTREPOIDS 1742201300 DESSUS 1880290200 CHARNIERE DROITE 1880290100 CHARNIERE GAUCHE 1880040100 SUPPORT CHARNIERE...
Page 6
2433 1881860100 GRILLE DE PANIER A COUVERTS 2610 1880240100 RAIL DE PANIER 2611 1880580100 EMBOUT DE RAIL ARRIERE 2612 1880570100 EMBOUT DE RAIL AVANT 3010 1746011886 BANDEAU 3310 1742181000 MANETTE PROGRAMMATEUR 3320 1742041000 BOUTON M / A 3321 1742191000 BOUTON DEPART 3510 1742170100 INTERCALAIRE 3511...
Page 7
7211 1746100100 BRAS DE LAVAGE INFERIEUR 7215 2002372100 COLLIER DE VIDANGE 7220 1746200100 BRAS DE LAVAGE SUPERIEUR 7221 1880900300 ENSEMBLE SUPPORT BRAS SUPERIEUR 7260 1881240100 CONDUIT INTERIEUR DU BRAS 7261 1737910100 GUIDE SUPPORT DE BRAS 7262 1733430100 LOGEMENT DE SUPPORT DE BRAS SUPERIEUR 7263 1881280100 JOINT ISOLATION 7264...
Page 9
Softening Adjustment: In order to enter the softening adjusting mode, select the knob position of 1 while the DW is out of energy (on/off is shut) then press the start button and energize the DW and keep pressing on the button for 5 seconds, after this DW enters the softening adjusting mode.
Page 10
Machine is not runnig Check supply, supply cord and Is start/stop cable connections indicator on? of the start/stop swicth Select the functional test mode, and start the functional test Check the door Does the drain switch and the pump work? connections Check overflow gauge...
Page 11
No water inlet to the machine -Check the water supply -Check the water inlet hose (twisted or not) -Check the sieves on the water inlet valve and the water inlet hose Check the Does the drain pump work or overflow gauge not at the water inlet stage and the cable connections...
Page 12
Machine takes less water Check the water inlet pressure (> 0,3 bar) Is water inlet valve Check the energized at the water inlet overflow gauge stage and connections Check the main Check the water Check the board and the inlet valve flowmeter connections TROUBLESHOOTING GUIDE FOR A3 TYPE DW’S...
Page 13
Machine takes much water and overflows Check the drain pump and the connections Select the funcitonal test mode. Start the functional test. Does the drain pump work? Check the over flow gauge, over flow switch and the connections Check the drain hose Check the water inlet valve...
Page 14
Machine indicates water inlet fault at the end of the functional test Any fault on the Fix the connection of the connections flowmeter? Check the Is the wiring of the connections, water inlet valve search for any correct? broken cable Check the main board and the connections...
Page 15
Machine indicates NTC or heater fault at the end of the functional test Establish proper Any problems with the connection connections of the NTC between main board and NTC Establish proper Any fault with the connection connections of the between main heater board and heater Check the heater...
Page 17
WHITE 0.35 YELLOW 0.35 BLUE 0.35 VIOLET 0.35 VIOLET 0.35 BLUE 0.35 YELLOW 0.35 Main Board ( Lamp side ) GREY 0.50 DRAIN Programme Select Switch VIOLET 1.50 VIOLET 0.50 GREEN 0.50 VIOLET 1.50 ORANGE 0.50 Malzem e / Material WHITE 0.50 Resim ism i / Draw ing nam e...
Page 18
Main Board KN 6 KN 5 KN 2 KN 1 KN 7 KN 8 02 01 Malzeme Renk Standart Ölçü Malzem e / Material Resim ism i / Draw ing nam e Main Switch Circulation Pump Terminal Block Thermic of Circulation Motor Tarih İsim Door Switch...