Page 2
All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice.
DO NOT ACCEPT VERBAL APPROVALS, BECAUSE THEY ARE NOT VALID. Honeywell never recommends using the PW-7000 or related products for use as a primary warning or monitoring system. Primary warning or monitoring systems should always meet local fire and safety code requirements. The installer must also...
Page 6
Inc. Copyright laws of the United States protect all information in this document or in the software product itself. Note: Any use of this product is subject to the terms and acceptance of the Honeywell, Inc. Software Agreement. Please request a copy from Honeywell, Inc., and review the agreement carefully.
In the event that a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to property of others, Customer shall immediately notify Honeywell in writing of all such claims. Honeywell shall defend or settle such claims and shall indemnify and hold Customer harmless for...
• If any other defect is apparent, call for a return authorization. Shipping Instructions To ship equipment back to Honeywell, Inc.: Step 1. Contact the customer service department at 800-323-4576 before returning equipment. When you call please have available: •...
All Products sold or licensed by Honeywell include a warranty registration card which must be completed and returned to Honeywell by or on behalf of the end user in order for Honeywell to provide warranty service, repair, credit or exchange.
Page 10
This page is intentionally left blank viii PW-7000 Output Module (PW7K1OUT) Installation Guide, Document 800-25675V1...
CHAPTER PW-7000 OUTPUT MODULE Description The Output Board provides connections for 16 relay outputs. You can either mount the board in a rack or open flat. If you rack-mount the board, only one edge is accessible for wiring; however, a flat mount increases the amount of available I/O slightly but significantly decreases the number of boards that can be mounted in one enclosure.
Specification The Output Board is for use in low voltage, class 2 circuits only. Primary power: 12VDC + 10%, 385mA maximum Relay contacts: Relays 0 through 15 outputs, Form-C, 2A @ 30VDC, resistive Inputs: Two unsupervised dedicated inputs Communication: RS-485 Range 9,600 to 38,400 bps Wire requirements: Power...
Selection 9,600 BPS 19,200 BPS 38,400 BPS* Not Used* * = Default LED Operation The Output Board uses two onboard LEDs to provide status information during the power-up sequence and during normal operation. Table 3: LED Settings Mode Description Power-up Start power-up, hardware setup.
Table 6: LEDs 1-4 LED number Description Start power-up, hardware setup Testing RAM Tamper Power Power The Output Board accepts 12VDC with an operating range of 10 to 14VDC and consumes 385 mA of current. Locate the power source as close to this board as possible.
Step 4. Use 24 AWG low capacitance, two twisted-pair, shielded cable (Belden 9842 or equiv.). Note: For RS-485 Communication Connections, twist the blue pair together and use as the common; use the orange pair as your data pair, observing polarity. Connect the external drain shield to the appropriate earth ground on one end.
Mounting Options This board can be mounted on-edge in the rack-mount enclosure provided by Honeywell, or it can be mounted flat against any surface using standoffs under the mounting holes provided in each of the four corners of this board.
Page 18
Step 5. Connect relay output wiring as appropriate. Step 6. Connect communications wiring to the Intelligent Controller. Step 7. Recheck wiring for correct connections and continuity. Step 8. When all boards have been installed, connect the power supply cord for proper connections and power.
Wiring Diagram for Connectors 1 through 8 Figure 1: PW-7000 Output Module Wiring: Connectors 1-8 Short OUTPUT BOARD RELAY0 NO together* RELAY0 C RELAY0 NC RELAY1 NO RELAY1 C RELAY1 NC RELAY2 NO RELAY2 C RELAY2 NC RELAY3 NO RELAY3 C RELAY3 NC RELAY4 NO RELAY4 C...
Wiring Diagram for Connectors 7 through 10 Figure 2: PW-7000 Output Module: Connectors 7-10 Tamper Switch (In CLOSED 16 OUTPUT BOARD position when Cabinet Door is Closed) +12VDC Power C - No Charging N/C - No Charging RELAY12 NC RELAY12 C RELAY12 NO RELAY13 NC PWR +...
Page 22
Honeywell Integrated Security, 135 W. Forest Hill Avenue Oak Creek, WI 53154 United States 800-323-4576 414-766-1798 Fax www.security.honeywell.com Discover | Customer Portal Self-Service Product Support and Learning Management System https://honeywelldiscovertraining.com/login/discover/default.asp ™ YouTube | Honeywell Help and Support https://www.youtube.com/channel/UCBEL6ouNV_LN5lEpYRujMTg/featured Document 800-25675V1...