Cisco Nexus 93180LC-EX ACI Installation Manual
Cisco Nexus 93180LC-EX ACI Installation Manual

Cisco Nexus 93180LC-EX ACI Installation Manual

Hide thumbs Also See for Nexus 93180LC-EX ACI:

Advertisement

Quick Links

Installing the Switch Chassis

Safety

Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for
the Cisco Nexus 3000 and 9000 Series for important Safety Information.
Warning
Statement 1071-Warning Definition
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with
standard practices for preventing accidents. Use the statement number provided at the end of each warning
to locate its translation in the translated safety warnings that accompanied this device.
SAVE THESE INSTRUCTIONS
Statement 1017-Restricted Area
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be accessed
only through the use of a special tool, lock and key, or other means of security.
Safety, page 1
Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide
1

Advertisement

loading

Summary of Contents for Cisco Nexus 93180LC-EX ACI

  • Page 1: Table Of Contents

    Starting the Switch, page 11 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071—Warning Definition IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger.
  • Page 2: Installation Options With Racks And Cabinets

    • Ensure that the site power meets the power requirements listed in Switch Power Input Requirements. If available, you can use an uninterruptible power supply (UPS) to protect against power failures. Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 3: Unpacking And Inspecting The Switch

    Compare the shipment to the equipment list provided by your customer service representative and verify that you have received all items, including the following: • Additional kits (includes the Accessory Kit). See the Additional Kits appendix for detailed information. Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 4: Installing The Switch

    • Make sure that the switch rack-mount kit includes the following parts: ◦ Front rack-mount brackets (2) ◦ Rear rack-mount brackets (2) ◦ Slider rails (2) ◦ M4 x 0.7 x 8-mm Phillips countersink screws (12) Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 5 Front rack-mount bracket aligned to the module end the chassis of the chassis Four M4 screws used to attach the bracket to the Four M4 screws used to attach the bracket to the chassis chassis Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 6 (see the following figure). Tighten 12-24 screws to 30 in-lb (3.39 N·m) of torque and tighten 10-32 screws to 20 in-lb (2.26 N·m) of torque. Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 7 Holding the switch with both hands, position the two rear rack-mount brackets on the switch between the rack or cabinet posts that do not have slider rails attached to them (see the following figure). Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 8 Holding the chassis level, insert two screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount brackets (using a total of four screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the following figure). Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 9: Grounding The Chassis

    You can alternatively ground the chassis (this is required if the rack is not grounded) by attaching a customer-supplied grounding cable to the chassis grounding pad and the facility ground. Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 10 2 M4 screws used to secure the grounding lug to the chassis Grounding cable, with 0.75 in. (19 mm) of insulation stripped from one end, inserted into the grounding lug and crimped in place Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 11: Starting The Switch

    Make sure that the connector clicks when fully pushed into the receptacle. b) Connect the other end of the power cable to a power source. Cisco Nexus 93180LC-EX ACI Mode Hardware Installation Guide...
  • Page 12 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.