g
GE
Lighting Solutions
READ THOROUGHLY BEFORE INSTALLING
Trunnion Mounted
(Standard)
SCREW B
BOLT A
WARNING
Risk of electric shock
• Turn power off before servicing
– see instructions
G E N E R A L
This luminaire is designed for outdoor lighting applica-
tions, and should not be used in areas of limited
ventilation or in high ambient temperature enclosures. Best
results will be obtained if installed and maintained
according to the following recommendations.
U N P A C K I N G
This luminaire has been properly packed so that no
parts should have been damaged during transit. Inspect to
confirm.
M O U N T I N G
CAUTION
Unit will fall if not installed properly
• Follow installation instructions
This floodlight is provided with either trunnion mount-
ing, pipe mounting, or wall mounting means.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred
to GE Lighting Solutions.
All manuals and user guides at all-guides.com
HLU, VLU Powerflood
Slipfitter Mounted
(Options K or S)
BOLT A
TRUNNION MOUNTED UNITS — Mounted directly on a
flat surface. Mounting adapters are available for installa-
tion on poles, crossarms, pipes, etc. The trunnion bracket
has a clearance hole for a 3/4-inch bolt used for attach-
ment to such mountings. The 0.562-inch holes on either
side permit additional anchoring, where required. Tighten
side trunnion bolts to 18 - 22 foot pounds.
PIPE MOUNTED UNITS — The slipfitter can be
mounted on 1-7/8-inch O.D. through 2-3/8-inch O.D. or
2-7/8-inch O.D. through 3-inch O.D. pipes. Three set
screws are used to clamp the floodlight securely to the pipe.
Tighten set screws to 18 - 22 foot pounds.
WALL MOUNTED UNITS - The wall mounting plate is
provided with four (4) 0.438-inch clearance holes spaced
4.375(H)x2.875(V) inches for mounting.
A I M I N G
Slightly loosen bolt "A" (two on trunnion, one on
slipfitter), tilt luminaire to desired position, and retighten
bolts. Both trunnions and slipfitters have vertical degree
scales which permit setting the floodlight at a selected
INSTRUCTIONS
®
Wall Mounted
(Option V)
HLUF
VLUF
GEH-3851C
Floodlight