For warranty service or repair, this product must be returned to a service facility designated by Hewlett-Packard (HP). Buyer shall pre- pay shipping charges to HP and HP shall pay shipping charges to return the product to Buyer. However, Buyer shall pay all shipping charges, duties, and taxes for products returned to HP from another country.
Return the product to a Hewlett-Packard Sales and Service Office for service and repair to ensure that safety features are maintained. HP E1364A 16-Channel Form C Switch Module User’s Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Supplementary Information: The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE-marking accordingly. Tested in a typical configuration in an HP B-Size VXI mainframe. April, 1995 Jim White, QA Manager European contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department HQ-TRE, Herrenberger Straße 130, D-71034 Böblingen, Germany (FAX +49-7031-14-3143).
Page 9
Notes HP E1364A 16-Channel Form C Switch Module User’s Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Please fold and tape for mailing Reader Comment Sheet HP E1364A 16-Channel Form C Switch Module User’s Manual Edition 2 You can help us improve our manuals by sharing your comments and suggestions. In appreciation of your time, we will enter you in a quarterly drawing for a Hewlett-Packard Palmtop Personal Computer (U.S.
Page 11
HP E1364A Form C Switch Module User’s Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
(for a Switchbox or Scanning Voltmeter Instrument). Switch Description The HP E1364A 16-Channel Form C Switch Module is a B-Size VXIbus and VMEbus register-based product which can be used for switching/scanning, control, and digital output applications. The switch can operate in a B-Size VXIbus or VMEbus mainframe or (with an adapter) in a C-Size VXIbus mainframe.
Page 13
NO, NC, and C terminal connectors on the terminal module. Figure 1-1. Form C Switch Simplified Diagram 12 Getting Started with the HP E1364A Chapter 1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
SCPI commands to be used. Guidelines to select SCPI commands for the Form C Switch follow. See the HP 75000 Series B Installation and Getting Started Guide for interface addressing and computer language information.
For a multiple-module switchbox, the card numbers are 01, 02,...,nn. The module with the lowest logical address is card number 01, the module with the next-lowest logical address is card number 02, etc. (See the HP 75000 Series B Installation and Getting Started Guide for a definition of logical addresses.)
(secondary address = 120/8 = 15) and queries the channel closure state. The result is returned to the computer and displayed (1 = channel closed, 0 = channel open). See the HP 75000 Series B Installation and Getting Started Guide for information on addressing.
Page 17
Notes 16 Getting Started with the HP E1364A Chapter 1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Also, the total current drawn by all circuits connected to the Form C Switch must not exceed the fuse rating for the supplies used. Chapter 2 Configuring the HP E1364A Form C Switch 17 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Figure 2-2 shows how to connect user (field) wiring to the connector block. Figure 2-1. Form C Switch Terminal Block 18 Configuring the HP E1364A Form C Switch Chapter 2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 20
Figure 2-2. Wiring the Form C Switch Terminal Block Chapter 2 Configuring the HP E1364A Form C Switch 19 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Form C Switch for the +12V supply. You should fuse all external equipment to ensure excess current is not drawn. 20 Configuring the HP E1364A Form C Switch Chapter 2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 22
+5V is applied to external relay 2. Figure 2-4. Example: Relay Control Configuration Chapter 2 Configuring the HP E1364A Form C Switch 21 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
00 relay is closed (NO connected to C), point A is at 0V. Figure 2-5. Example: Digital Output Configuration 22 Configuring the HP E1364A Form C Switch Chapter 2 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Replace fuses on the switch component module See Figure 2-6 for component locations. Figure 2-6. Form C Switch Component Locations Chapter 2 Configuring the HP E1364A Form C Switch 23 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Module Front Panel Connections If you choose not to use the supplied connector block, Figure 2-7 shows the E1364A front panel and the connection diagram for wiring your own terminal connector. Figure 2-7. E1364A Front Panel and Wiring Diagram 24 Configuring the HP E1364A Form C Switch Chapter 2 Artisan Technology Group - Quality Instrumentation ...
TRIG:SOUR Selects the trigger source to advance the scan. BUS I EXT I HOLD I IMM Chapter 3 Using the HP E1364A Form C Switch 25 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
00 is the channel number. To open channel 00, use OPEN (@100) Figure 3-1. Example: Voltage Switching 26 Using the HP E1364A Form C Switch Chapter 3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 28
This example shows one way that the Form C Switch can be used to control Microwave Relays an (external) microwave relay. Figure 3-2 shows an HP 33311B Microwave Relay connected to channel 00 of a Form C Switch. The + 5V source for the microwave relay is provided via channel 15 of the Form C Switch (via JM148, JM145, and the channel 15NO terminal).
Page 29
HP 33300 40 dB step. Additional drive relays are required Attenuators for the 10 dB and 20 dB steps.) The HP 8761A and HP 33300A/C operate from a 12-15V coil voltage, while the HP 8761B and HP 33300B/D operate from a 24V-30V coil voltage.
Page 30
00 is the channel number. To open channel 00, use OPEN (@100) Figure 3-4. Example: Digital Output Configuration Chapter 3 Using the HP E1364A Form C Switch 29 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
(one at a time), but the sequence in which multiple channels are closed with a single command is not guaranteed. 30 Using the HP E1364A Form C Switch Chapter 3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
For this example, the mainframe and instrument are connected via HP-IB to an HP E1300A/E1301A mainframe with an address of 709 and an external instrument (such as an HP 3457A Multimeter) with an address of 722. The Form C Switch is at logical address 120 (secondary address 15).
1 to 32767 scans. Use INITiate:CONTinous ON to set continuous scanning. See Chapter 4 for details. 32 Using the HP E1364A Form C Switch Chapter 3 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
TRIG:SOUR specifies the source to advance the scan. Use the TRIG command to advance the scan when TRIG:SOUR BUS or TRIG:SOUR HOLD is set. The OUTP command enables the HP E1300A/E130lA or HP E1405/E1406 Trig Out port. Figure 4-2 shows scanning trigger sources.
Page 35
TRIG:SOUR BUS or TRIG:SOUR HOLD. Command not usable with TRIG:SOUR EXT or TRIG:SOUR IMM. Figure 4-1. Scanning Channels Commands 34 Understanding the HP E1364A Form C Switch Chapter 4 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 36
The TRIG OUT port outputs a +5 V negative-going pulse. Figure 4-2. Scanning Trigger Sources Chapter 4 Understanding the HP E1364A Form C Switch 35 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 37
HP E1300A/E1301A Trig Out BNC port is connected to the instrument External Trigger In port. For this example, the mainframe and instrument are connected via HP-IB with mainframe address of 709 and instrument address of 722. The Form C Switch is at logical address 120 (secondary address 15).
Page 38
See the following figure for typical user connections. For this Event In Ports example, the mainframe and instrument are connected via HP-IB with mainframe address of 709 and instrument address of 722. The Form C Switch logical address is 120 (secondary address = 120/8 = 15).
STATus:OPERation[:EVENt]? command in Chapter 5 for an example. When enabled by the STAT:OPER:ENAB 256 command, the Scan Complete bit will be reported as bit 7 of the Status Register. Use the HP-IB Serial Poll or the IEEE 488.2 Common Command *STB? to read the Status Register.
Subsequent queries continue to read the error queue until it is empty. The maximum <err_message> string length is 255 characters. 40 Understanding the HP E1364A Form C Switch Chapter 4 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Instruments (SCPI) and IEEE 488.2 Common (*) commands. See the HP 75000 Series B B-Size VXIbus Mainframe HP E1300A/E130lA User’s Manual or the HP 75000 Series C HP E1405A User’s Manual for additional information on SCPI and common commands. Chapter contents are: •...
25, you can send either of the following command statements: SOUR:PULS:COUN 25 or PULS:COUN 25 42 HP E1364A Form C Switch Command Reference Chapter 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Linking Multiple SCPI Commands: Use both a semicolon (;) and a colon (:) between the commands. For example: ARM:COUN 1;:TRIG:SOUR EXT Chapter 5 HP E1364A Form C Switch Command Reference 43 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
"Reset Instr" or "Clear Instr" keys can be used to stop the scan. When the scan is enabled from the interface and TRIG:SOUR BUS or HOLD is set, use ABORt or the HP E130lA front panel "Reset Instr" or "Clear Instr" keys to stop the scan.
10. ARM COUN 10 Set 10 scans per INIT command ARM COUN? Query number of scans 46 HP E1364A Form C Switch Command Reference Chapter 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
The DISPlay subsystem monitors the channel state of a selected module (or card) in a switchbox. This subsystem operates only with mainframes which have a display, such as the HP 75000 Series B mainframe (HP Model Number E130lA). Subsystem Syntax...
DISPlay:MONitor:CARD <number> |AUTO command to select the module. • Monitor Mode on an HP E1301A Mainframe Display: A typical display for the HP E1364A Form C Switch module follows, where all channels (all relays) are closed. 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 • *RST Condition: DISPlay:MONitor[:STATe] OFF | 0...
[:STATe] OUTPut[:STATe] < mode > enables or disables the "Trig Out" BNC port on the rear panel of the HP E1300A/E1301A Mainframes or on the HP E1405/E1406 Command Modules. OUTPut[:STATe] ON | 1 enables the port and OUTPut[:STATe] OFF | 0 disables the port.
Close channels 100 and 213. 100 closes channel 00 of card #1 and 213 closes channel 13 of card #2. 52 HP E1364A Form C Switch Command Reference Chapter 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Open channels 100 and 213. 100 opens channel 00 of #1 and 213 opens channel 13 of card #2. Chapter 5 HP E1364A Form C Switch Command Reference 53 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
See Chapter 4, "Example: Scanning With External Devices" or "Example: Scanning Using Trig Out and Event In Ports" for example scanning programs using external instruments. 54 HP E1364A Form C Switch Command Reference Chapter 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Register. Returns + 256 if bit 8 is set to 1 or returns + 0 if bit 8 is set to 0. Chapter 5 HP E1364A Form C Switch Command Reference 55 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
SYSTem:ERRor? command returns 0, "No error". To clear all error numbers/messages in the queue, execute the *CLS command. 56 HP E1364A Form C Switch Command Reference Chapter 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Form C Switch Module Model Number: The SYSTem:CTYPe? <number> command returns: HEWLETT-PACKARD,E1364A,0,A.01.00 where the 0 after E1364A is the module serial number (always 0) and A.01.00 is an example of the module revision code number. Example Reading the Model Number of a Card#1 Module:...
BUS or TRIGger:SOURce HOLD commands remain in effect after triggering a switchbox with the TRIGger[:IMMediate] command. • Related Commands: INITiate, [ROUTe:]SCAN 58 HP E1364A Form C Switch Command Reference Chapter 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Using External Trigger Inputs: With TRIGger:SOURce EXTernal selected, only one switchbox at a time can use the external trigger input at the HP E130OA/E1301A mainframe "Event In" BNC port. The trigger input is assigned to the first switchbox that requested the external trigger source (with a TRIGger:SOURce EXTernal command).
This example uses external triggering (TRIG:SOUR EXT) to scan channels 00 through 03 of a single-module switchbox. The trigger source to advance the scan is the input to the "Event In" BNC on an HP E1300A/E1301A Mainframe. When INIT is executed, the scan is started and channel 00 is closed.
Store instrument state See note below Note: These commands apply to many instruments and are not documented in detail here. See the HP 75000 Series B E1300/E1301 Mainframe User’s Manual or the ANSI/IEEE Standard 488.2-1987 for more information. Chapter 5 HP E1364A Form C Switch Command Reference 61 Artisan Technology Group - Quality Instrumentation ...
When scan is enabled and trigger source is TRIG:SOUR BUS, use the *TRG command to trigger the switchbox to advance the scan. *TST? Self-Test Always returns 0. 62 HP E1364A Form C Switch Command Reference Chapter 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Relays that wear out normally or fail due to misuse should not be considered defective and are not covered by the product’s warranty. 64 HP E1364A Specifications Appendix A Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Appendix B HP E1364A Form C Switch Registers Register Definitions The HP E1364A Form C Switch is a register-based device. See Figure B-1. ID Register b + 00 Write Undefined (Logical Address) Read* Reg-Base Manufacturer ID * Returns FFF = Hewlett-Packard A16 only register-based...
To read or write to specific registers, you must use the register address. Since the addresses for HP 75000 Series B or Series C plug-in modules are A00 through A15, use the VME A16 mnemonic for the address space. The address space within the mainframe/command module memory map depends on the mainframe/command module used.
Channel Enable register to close channel 02. Or, write a "0" to bit 14 of the register to open channel 14. Appendix B HP E1364A Form C Switch Registers 67 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 69
Notes 68 HP E1364A Form C Switch Registers Appendix B Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Sending a command requiring a < channel_list > without the < channel_list >. 2601 Channel list required Appendix C HP E1364A Form C Switch Error Messages 69 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 71
Notes 70 HP E1364A Form C Switch Error Messages Appendix C Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 72
:CDEScription? 57 DISP:MON[:STAT] 48 Certification 5 DISPlay Subsystem 47 Channel Addresses 13 Documentation history 6 Channel List 34 HP E1364A 16 Channel Form C Switch Module Index Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 73
Interrupt PriorityLogical Address 23 Register Reading 66 Registers 65 - 68 Relay Configuration 20 Relay Control Configuration 20 HP E1364A 16 Channel Form C Switch Module Index Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 74
Switch Description 11 Switch Registers 65 - 68 Switchbox 13 Switching Channels 26 SYSTem Subsystem 56 SYSTem:CDEScription? 57 HP E1364A 16 Channel Form C Switch Module Index Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...