JY997D66401B
Side
JAPANESE
A
Side
ENGLISH
B
MELSEC iQ-F FX5-4AD-PT-ADP
Hardware Manual
Manual Number
JY997D66401
Revision
B
Date
October 2019
This manual describes the part names, dimensions, installation, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration:
The company names, system names and product names mentioned in this
manual are either registered trademarks or trademarks of their respective
companies. In some cases, trademark symbols such as '' or '
' are not specified
in this manual.
Effective October 2019
Specifications are subject to change without notice.
2016 MITSUBISHI ELECTRIC CORPORATION
Safety Precautions
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in minor or moderate injury or
property damage.
Depending on the circumstances, procedures indicated by
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
MELSEC iQ-F
Describes the analog
FX5 User's Manual
function of the CPU module
JY997D60501
(Analog Control - CPU module
built-in and the analog
built-in, Expansion adapter)
adapter.
Explains FX5UJ CPU module
MELSEC iQ-F
specification details for I/O,
FX5UJ User's Manual
SH-082206ENG
wiring, installation, and
(Hardware)
maintenance.
Explains FX5U CPU module
MELSEC iQ-F
specification details for I/O,
FX5U User's Manual
JY997D55301
w i r i n g , i n s t a l l a t i o n , a n d
(Hardware)
maintenance.
Explains FX5UC CPU
MELSEC iQ-F
module specification details
FX5UC User's Manual
JY997D61301
for I/O, wiring, installation,
(Hardware)
and maintenance.
How to obtain manuals
For the necessary product manuals or documents, consult with your local
Mitsubishi Electric representative.
Side
B
Applicable standards
FX5-4AD-PT-ADP comply with the EC Directive (EMC Directive) and UL standards
(UL, cUL). Further information can be found in the following manual.
MELSEC iQ-F FX5UJ User's Manual (Hardware)
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
Regarding the standards that relate to the CPU module, please refer to either the
product catalog or consult with your nearest Mitsubishi product provider.
Attention
This product is designed for use in industrial applications.
Caution for EC Directive
Installation in Enclosure
Programmable controllers are open-type devices that must be installed and used
within conductive control cabinets. Please use the programmable controller while
installed within a conductive shielded control cabinet. Installation within a control
cabinet greatly affects the safety of the system and aids in shielding noise from the
programmable controller.
Control cabinet
- The control cabinet must be conductive.
- Ground the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door,
connect the cabinet and its doors with thick wires.
- In order to suppress the leakage of radio waves, the control cabinet structure
must have minimal openings. Also, wrap the cable holes with a shielding cover or
other shielding devices.
- The gap between the control cabinet and its door must be as small as possible by
attaching EMI gaskets between them.
Shielding cover
Shielded cable
EMI gasket
Wires
*1
*1 These wires are used to improve the conductivity between the door and control
cabinet.
Cables
- Make sure to use shielded cables as cables pulled out of the control cabinet.
- Connect the shield such as shielded cables and shielding covers to the grounded
control cabinet.
It is possible that the accuracy temporarily fluctuates within ±10 %.
1. Outline
may also
FX5-4AD-PT-ADP expansion adapter for resistance temperature detector temperature
sensor input (hereinafter called PT-ADP) is an expansion adapter for connecting a
resistance temperature detector (Pt100, Ni100 3-wire type) temperature sensor, and
measuring 4 channels of temperature.
1.1 Incorporated Items
Verify that the following product and items are included in the package:
FX5-4AD-PT-ADP resistance temperature detector temperature
Product
sensor input expansion adapter
Hardware manual [Japanese /English] (This manual)
Included Items
Hardware manual [Chinese]
1.2 External Dimensions, Part Names, and Terminal Layout
[10]
[5]
[3]
[4]
[6]
[2]
[7]
[8]
[1]
8
[9]
15.1
74
15.1
17.6
Special adapter
[11]
connector cover is
removed
Weight: Approx. 0.1 kg
Outer painting color: Munsell 0.6B7.6/0.2
[1] DIN rail mounting groove (DIN rail: DIN46277, 35 mm wide)
[2] Name plate
[3] Expansion adapter slide lock
[4] Expansion adapter connector cover
[5] Direct mounting hole: 2 holes of 4.5 (mounting screw: M4 screw)
[6] PWR LED (green)
[7] Terminal block (European type terminal block)
[8] Expansion adapter connector
[9] DIN rail mounting hook
[10] Expansion adapter fixing hook
[11] Expansion adapter connector
2. Installation
INSTALLATION
PRECAUTIONS
Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
Use the product within the generic environment specifications described in the
User's Manual (Hardware) for the CPU module to be used.
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
, H
S, SO
or NO
), flammable gas, vibration or
2
2
2
2
impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
INSTALLATION
PRECAUTIONS
Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformities.
Install the product securely using a DIN rail or mounting screws.
Connect the expansion board and expansion adapter securely to their designated
connectors.
Loose connections may cause malfunctions.
For the installation, refer to the following manual.
MELSEC iQ-F FX5UJ User's Manual (Hardware)
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)
3. Wiring
Unit: mm
WIRING PRECAUTIONS
Terminal
Make sure to cut off all phases of the power supply externally before
layout
attempting installation or wiring work.
L1+
Failure to do so may cause electric shock or damage to the product.
Make sure to properly wire to the terminal block (European type) in
L1-
accordance with the following precautions.
I1-
Failure to do so may cause electric shock, equipment failures, a short-circuit,
L2+
wire breakage, malfunctions, or damage to the product.
L2-
- The disposal size of the cable end should follow the dimensions described
I2-
in the manual.
- Tightening torque should follow the specifications in the manual.
L3+
- Twist the ends of stranded wires and make sure that there are no loose
L3-
wires.
I3-
- Do not solder-plate the electric wire ends.
L4+
- Do not connect more than the specified number of wires or electric wires
L4-
of unspecified size.
I4-
- Affix the electric wires so that neither the terminal block nor the connected
parts are directly stressed.
•
WIRING PRECAUTIONS
When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to malfunction of the PLC caused
by abnormal data written to the PLC due to the effects of noise:
1) Do not bundle the power line or analog input/output cable together with or
lay them close to the main circuit, high-voltage line, load line or power
line. As a guideline, lay the power line, control line and communication
cables at least 100 mm away from the main circuit, high-voltage line, load
line or power line.
2) Ground the shield of the analog input/output cable at one point on the
signal receiving side.
However, do not use common grounding with heavy electrical systems.
3.1 Cable End Treatment And Tightening Torque
3.1.1
European type terminal block
1) Wiring type
Use the wire supplied together with Pt100/Ni100 or a shielded twisted wire
when wiring the Pt100/Ni100 resistance temperature detector.
2) Suitable wiring
Wire size
No. of wire
per terminal
Single wire, Strand wire Ferrules with insulating sleeve
AWG22 to 20
One wire
2
(0.3 to 0.5 mm
)
2
Two wires
AWG22 (0.3 mm
)
3) Tightening torque
Tighten the terminal screws with 0.20 Nm.
Do not tighten the screws outside the specified torque.
Failure to do so may cause equipment failures or malfunctions.
4) Wire end treatment
Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
When using a wire ferrule with an insulating sleeve, choose a wire with
proper cable sheath referring to the above outside dimensions, otherwise
the wire cannot be inserted easily.
- Strand wire/single wire
- Stick terminal with insulating sleeve
Insulation sleeve
9 mm
2.6 mm
<Reference>
Manufacturer
Model
Phoenix Contact GmbH & Co. KG
AI 0.5-8 WH
AWG22 to 20
2
(0.3 to 0.5 mm
)
-
Contact area
(Crimp area)
8 mm
14 mm
Caulking tool
CRIMPFOX 6
CRIMPFOX 6T-F