Ex66
VSC motor plug not connected
Ex67
VSC Current Trip Failure
Ex68
VSC over current Failure
Ex69
VSC - motor not following
Ex6A
VSC Board overheating
Ex6B
VSC under voltage Failure
Ex6C
VSC over voltage Failure
Ex6D
VSC Failure
Ex6E
VSC unknown message Failure
Ex6F
VSC Failure
Technical Support - A.D.L.
Full name
 Stops cycle execution
 Stops cycle execution
 Stops cycle execution
 Stops cycle execution
 Stops cycle execution
 Stops cycle execution
 Stops cycle execution
 No Action
 Stops cycle execution
 Stops cycle execution
Action
53/66
Notes and possible causes
 Motor Wiring
 Motor Windings
 VSC Board
 VSC Board - Motor Wiring
 Motor Connector
 VSC Board
 VSC Board - Motor Wiring
 Motor Connector
 Motor mechanincal blockage
 VSC Board
 VSC Board - Motor Wiring
 Motor Connector
 Motor mechanincal blockage
 VSC Board
 Motor mechanincal blockage
 VSC Board
 Main Board - VSC power supply wiring
 VSC Board Failure
 VSC BOARD Failure
----------------
 Main Board - VSC communication wiring
 Main Board - VSC power supply wiring
 Main Board or VSC Board Failure
 VSC BOARD Failure
599 74 32-54 Rev.01