INSTRUCTION MANUAL
D1xB2X05, D1xB2X10 & D1xB2X15
Xenon Beacons with relay / telephone initiation
For use in Hazardous Locations
1) Warnings
• DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
• DO NOT OPEN WHEN ENERGISED
• POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
• HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
• DO NOT PAINT
• TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES, THE FIRST
CONDUIT RUN MUST HAVE A SEALING
FITTING CONNECTED WITHIN 18 INCHES
OF ENCLOSE. SUBSEQUENT CONDUIT
RUNS MUST HAVE A SEALING FITTING
CONNECTED AS CLOSE AS PRACTICAL TO
THE WALL OF THE ENCLOSURE, BUT IN
NO CASE MORE THAN THE SIZE OF THE
CONDUIT OR 50MM, WHICHEVER IS THE
LESSER.
• TO PREVENT IGNITION OF GROUP A, B, C
AND D ATMOSPHERES - SEE
INSTRUCTION FOR CHEMICAL
COMPATIBILITY
2) Rating & Marking Information
2.6 ATEX / IECEx & UKEx Certification
The D1xB2X Xenon beacons comply with the following
standards:
EN IEC60079-0:2018 / IEC60079-0:2017 (Ed 7)
EN60079-1:2014 / IEC60079-1 (Ed. 7) (2014)
EN60079-31:2014 / IEC60079-31 (Ed. 2) (2013)
The D1xB2X05DC012-T, D1xB2X05DC024-T &
D1xB2X05DC048-T Xenon Beacons are rated as follows:
Ex db IIC T4 Gb Ta -55°C to +80°C
Ex db IIC T5 Gb Ta -55°C to +75°C
Ex db IIC T6 Gb Ta -55°C to +60°C
Ex tb IIIC T104°C Db Ta -55°C to +80°C
E2S Warning Signals
Impress House, Mansell Road, Acton, London W3 7QH
Document No. D191-00-581-IS
Issue 1
15-11-2023
D1xB2X05-T
D1xB2X10-T
D1xB2X15-T
The D1xB2X05AC115-T & D1xB2X05AC230-T Xenon
Beacons are rated as follows:
Ex db IIC T4 Gb Ta -55°C to +70°C
Ex db IIC T5 Gb Ta -55°C to +50°C
Ex tb IIIC T116°C Db Ta -55°C to +70°C
The D1xB2X10DC024-T & D1xB2X10DC048-T Xenon
Beacons are rated as follows:
Ex db IIC T4 Gb Ta -55°C to +80°C
Ex db IIC T5 Gb Ta -55°C to +45°C
Ex tb IIIC T135°C Db Ta -55°C to +80°C
The D1xB2X10AC115-T, D1xB2X10AC230-T,
D1xB2X15AC115-T & D1xB2X15AC230-T Xenon Beacons
are rated as follows:
Ex db IIC T3 Gb Ta -55°C to +70°C
Ex db IIC T4 Gb Ta -55°C to +65°C
Ex tb IIIC T139°C Db Ta -55°C to +70°C
The D1xB2X15DC024-T & D1xB2X15DC048-T Xenon
Beacons are rated as follows:
Ex db IIC T3 Gb Ta -55°C to +80°C
Ex db IIC T4 Gb Ta -55°C to +65°C
Ex tb IIIC T146°C Db Ta -55°C to +80°C
Certificate No.
ATEX Mark,
Equipment Group and
Category:
CE Marking and
Notified Body No.
UKCA Marking and
Notified Body No.
The units can be installed in locations with the following
conditions:
www.e2s.com
DEMKO 19 ATEX 2009X
IECEx ULD 19.0006X
UL21UKEX2130X
II 2G
II 2D
2813
0518
Tel: +44 (0)208 743 8880