hit counter script
Download Print this page
E2S D1xB2X05 Series Instruction Manual

E2S D1xB2X05 Series Instruction Manual

Xenon beacons with relay / telephone initiation for use in hazardous locations
Hide thumbs Also See for D1xB2X05 Series:

Advertisement

Quick Links

INSTRUCTION MANUAL
D1xB2X05, D1xB2X10 & D1xB2X15
Xenon Beacons with relay / telephone initiation
For use in Hazardous Locations
1) Warnings
• DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
• DO NOT OPEN WHEN ENERGISED
• POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
• HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
• DO NOT PAINT
• TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES, THE FIRST
CONDUIT RUN MUST HAVE A SEALING
FITTING CONNECTED WITHIN 18 INCHES
OF ENCLOSE. SUBSEQUENT CONDUIT
RUNS MUST HAVE A SEALING FITTING
CONNECTED AS CLOSE AS PRACTICAL TO
THE WALL OF THE ENCLOSURE, BUT IN
NO CASE MORE THAN THE SIZE OF THE
CONDUIT OR 50MM, WHICHEVER IS THE
LESSER.
• TO PREVENT IGNITION OF GROUP A, B, C
AND D ATMOSPHERES - SEE
INSTRUCTION FOR CHEMICAL
COMPATIBILITY
2) Rating & Marking Information
2.6 ATEX / IECEx & UKEx Certification
The D1xB2X Xenon beacons comply with the following
standards:
EN IEC60079-0:2018 / IEC60079-0:2017 (Ed 7)
EN60079-1:2014 / IEC60079-1 (Ed. 7) (2014)
EN60079-31:2014 / IEC60079-31 (Ed. 2) (2013)
The D1xB2X05DC012-T, D1xB2X05DC024-T &
D1xB2X05DC048-T Xenon Beacons are rated as follows:
Ex db IIC T4 Gb Ta -55°C to +80°C
Ex db IIC T5 Gb Ta -55°C to +75°C
Ex db IIC T6 Gb Ta -55°C to +60°C
Ex tb IIIC T104°C Db Ta -55°C to +80°C
E2S Warning Signals
Impress House, Mansell Road, Acton, London W3 7QH
Document No. D191-00-581-IS
Issue 1
15-11-2023
D1xB2X05-T
D1xB2X10-T
D1xB2X15-T
The D1xB2X05AC115-T & D1xB2X05AC230-T Xenon
Beacons are rated as follows:
Ex db IIC T4 Gb Ta -55°C to +70°C
Ex db IIC T5 Gb Ta -55°C to +50°C
Ex tb IIIC T116°C Db Ta -55°C to +70°C
The D1xB2X10DC024-T & D1xB2X10DC048-T Xenon
Beacons are rated as follows:
Ex db IIC T4 Gb Ta -55°C to +80°C
Ex db IIC T5 Gb Ta -55°C to +45°C
Ex tb IIIC T135°C Db Ta -55°C to +80°C
The D1xB2X10AC115-T, D1xB2X10AC230-T,
D1xB2X15AC115-T & D1xB2X15AC230-T Xenon Beacons
are rated as follows:
Ex db IIC T3 Gb Ta -55°C to +70°C
Ex db IIC T4 Gb Ta -55°C to +65°C
Ex tb IIIC T139°C Db Ta -55°C to +70°C
The D1xB2X15DC024-T & D1xB2X15DC048-T Xenon
Beacons are rated as follows:
Ex db IIC T3 Gb Ta -55°C to +80°C
Ex db IIC T4 Gb Ta -55°C to +65°C
Ex tb IIIC T146°C Db Ta -55°C to +80°C
Certificate No.
ATEX Mark,
Equipment Group and
Category:
CE Marking and
Notified Body No.
UKCA Marking and
Notified Body No.
The units can be installed in locations with the following
conditions:
www.e2s.com
DEMKO 19 ATEX 2009X
IECEx ULD 19.0006X
UL21UKEX2130X
II 2G
II 2D
2813
0518
Tel: +44 (0)208 743 8880
Sheet 1 of 6

Advertisement

loading

Summary of Contents for E2S D1xB2X05 Series

  • Page 1 The units can be installed in locations with the following Ex db IIC T6 Gb Ta -55°C to +60°C conditions: Ex tb IIIC T104°C Db Ta -55°C to +80°C E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 2 -55°C to +70°C (D1xB2X05AC-T, D1xB2X10AC-T, D1xB2X15AC-T) The certification approval has validated continuous use up to 38°C ambient and are for transient use up to 80°C ambient. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 3 Additionally, the beacon can be mounted using the ratchet adjustable stainless-steel wall bracket assembly. This is available as an accessory – part code: SP77-0001. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 4 Table 3: Switch Positions for Flash Patterns The earth conductor should be at least equal in size and rating to the incoming power conductors. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 5 If the unit is set to Option A the beacon will not work DIP Switch S1 effectively. Fig 7 : Input Wiring, DIP settings and Header Positions E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
  • Page 6 The beacon is activated on the first telephone ring (or relay The Beacon lens cover is interchangeable, contact E2S Ltd for pulsed input) and any other subsequent inputs and will a replacement lens cover available in various colours.
  • Page 7 16/03/2023 WRITTEN CONSENT. IMPRESS HOUSE STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER ALTERNATIVE MATERIAL AS PER LATEST DATE OF ISSUE SHOWN ABOVE LONDON W3 7QH SCALE SHEET APPROVED DATE ALERTALARM RANGE D250-06-001 WWW.E2S.COM NTS 1 16/03/2023 R.N.POTTS...
  • Page 8 EU Certificate of Conformity for the Quality Assurance System (Module MEDD00000GV Standards applied: EN 54-3:2014 incl. A1: 2019 EN 54-23:2010 IEC 60092-504: 2016 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-077_Issue_G - Page 1 of 2 - QAF_252_Issue_5...
  • Page 9 This Declaration is issued under the sole responsibility of the manufacturer. Desmond Gayler Document No.: DC-077_Issue_G Quality Assurance Manager Date and Place of Issue: London, 01/09/2023 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-077_Issue_G - Page 2 of 2 - QAF_252_Issue_5...
  • Page 10 UK Certificate of Conformity for the Quality Assurance System (Module MERD00000GV Standards applied: EN 54-3:2014 incl. A1: 2019 EN 54-23:2010 IEC 60092-504: 2016 IEC 60533: 2015 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-096_Issue_C - Page 1 of 2 - QAF_252_Issue_5...
  • Page 11 This Declaration is issued under the sole responsibility of the manufacturer. Desmond Gayler Document No.: DC-096_Issue_C Quality Assurance Manager Date and Place of Issue: London, 18/03/2024 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-096_Issue_C - Page 2 of 2 - QAF_252_Issue_5...