Disk enclosure installation instructions
Hide thumbs Also See for P6000:

Advertisement

HP P6300/P6500 EVA M6612/M6625 Disk
Enclosure Installation Instructions
HP Part Number: 5697-0179
Published: May 201 1
Edition: 1

Advertisement

loading

Summary of Contents for HP P6000

  • Page 1 HP P6300/P6500 EVA M6612/M6625 Disk Enclosure Installation Instructions HP Part Number: 5697-0179 Published: May 201 1 Edition: 1...
  • Page 2 © Copyright 201 1 Hewlett-Packard Development Company, L.P.
  • Page 3: About This Document

    About this document This document describes how to install an M6612 or M6625 disk enclosure into a rack as part of an P6300/P6500 EVA storage array. The disk enclosure installation may be performed while the array is in operation. You can only add one disk enclosure online at a time. These instructions do not include adding an expansion rack.
  • Page 4 Secure rack rails to the front and back rack columns using screws. Make sure that the shoulders of the screws fit inside the square or round holes of the rack (2, Figure NOTE: If installing rails in a square hole rack, use larger-sized shoulder screws and pins for mounting.
  • Page 5: Installing The Disk Enclosure

    Installing the disk enclosure Slide the device into position on the rails (1, Figure 2 (page 5)) and then tighten the thumbscrews (2) on the front of the device to secure the device to the rack. Figure 2 Secure disk enclosure to rack NOTE: The rear ends of the rails have a CTO bracket that must engage the device chassis to secure the rear of the chassis to the rails.
  • Page 6 Figure 4 Installing tie wraps and routing cables Populate the enclosure with available disk drives (not included with this kit). Start with the lowest number in for the M6625, and Figure 7 (page 6) for the M6612, and continue in order until you have inserted the desired number.
  • Page 7: Cabling The Enclosure

    Insert drive blank into any slots without a disk drive. Push the drive blank until you detect a click. Figure 8 Inserting a drive blank Cabling the enclosure Two methods are described for cabling a new disk enclosure. The online method allows a disk enclosure to be added to a powered, operational array.
  • Page 8 Cabling the P6300 EVA enclosure while offline Power down the array. Figure 9 (page 8) shows the cabling for an array with one P6300 EVA controller enclosure and two disk enclosures. Figure 9 Cabling for preexisting P6300 EVA Figure 10 (page 8) shows the cabling when two disk enclosures are added to the array.
  • Page 9 Table 1 Adding disk enclosures to the P6300 EVA callouts Callout Description Connects controller 1, DP-B to newly installed I/O module B, port P2 (closest to controller enclosure) Connects I/O module B, port P2 to I/O module B, port P1 between newly installed disk enclosures Connects existing I/O module B, port P2 (bottom of rack) to topmost, newly installed I/O module B, port P1 Connects topmost, newly installed I/O module A, port P1 to bottom existing I/O module A, port P2...
  • Page 10 13. Verify the status of the newly installed disk enclosure: Open HP P6000 Command View. Navigate to the newly added disk enclosure within the Hardware folder in the navigation pane and select it. The Disk Enclosure Properties window opens. Select the I/O tab and verify that the Operational state for both ports on both I/O modules is Good.
  • Page 11 With only one I/O module from the newly added enclosure cabled to the array, there will be HP P6000 Command View warnings that indicate disk drives in the system are only connected on one of the redundant loops. This is to be expected, and the warnings should clear as soon as the other I/O module is connected.
  • Page 12 For the I/O module that you connected, check that the overall operational state and the connection and operational states for each port displays Good. The other I/O module that is not yet connected will display Not installed for the overall operational state and Not available for each port operational state.
  • Page 13 Cabling the P6500 EVA enclosure while offline Adding below the controller enclosure Power down the array and existing disk enclosures. Figure 12 (page 13) shows the cabling for an array with one P6500 EVA controller enclosure and four disk enclosures. With the P6500 EVA, disk enclosure are balanced as evenly as possible above and below the controller enclosures.
  • Page 14 Figure 13 Adding a disk enclosure below the P6500 EVA Table 3 Adding a disk enclosure below the P6500 EVA callouts Callout Description Connects installed I/O module A, port P1 (below controller) to controller 1, port DP-A (using the DP- 1 cable) Connects installed I/O module A, port P2 (below controller) to existing I/O module, port P1 Connects installed I/O module B, port P1 (below controller) to controller 2, port DP-B (using the DP- 1...
  • Page 15 Adding above the controller enclosure Complete the following procedure to add a disk enclosure above the controller enclosure. Figure 14 (page 15) shows the cabling when a disk enclosure is added above the controller enclosure. Unplug the DP-2 cable from I/O module port P1 of the existing disk enclosure nearest the newly installed disk enclosure and plug it into port P1 of I/O module A of the newly installed disk enclosure (1, Figure 14 (page...
  • Page 16 With only one I/O module from the newly added enclosure cabled to the array, there will be HP P6000 Command View warnings that indicate disk drives in the system are only connected on one of the redundant Fibre Channel loops. This is to be expected, and the warnings should clear as soon as the other I/O module is connected.
  • Page 17 Complete the following steps to verify: Open HP P6000 Command View. Navigate to the newly added disk enclosure within the Hardware folder in the navigation pane and select it.