THIS APPARATUS MUST BE EARTHED. Before operating the unit, please read this manual thoroughly and retain it for future reference. This apparatus is provided with a main switch on the rear panel. For SRPC-5 Install this apparatus so that user can access the main switch easily.
Page 3
CAUTION 4. Prevention against achieving hazardous condition due to uneven mechanical loading The apparatus shall not be exposed to dripping or When this product is installed in a rack, please make splashing. No objects filled with liquids, such as vases, sure that the rack does not achieve hazardous condition shall be placed on the apparatus.
Page 4
TV studio). moisture. For the customers in Europe The manufacturer of this product is Sony Corporation, 1- To avoid electrical shock, do not open the 7-1 Konan, Minato-ku, Tokyo, Japan. cabinet. Refer servicing to qualified...
Page 5
For the customers in Europe The manufacturer of this product is Sony Corporation, 1- 7-1 Konan, Minato-ku, Tokyo, 108-0075 Japan. The Authorized Representative for EMC and product safety is Sony Deutschland GmbH, Hedelfinger Strasse 61, 70327 Stuttgart, Germany.
Table of Contents Overview................7 Features ................... 7 System Configuration Example ..........7 Names and Functions of Parts ..........9 Front ..................9 Rear ..................10 Setup..................11 Setup Flow ................11 Preparation ................11 Shared File Server Settings ........... 11 Displaying the Web Application Screen .......
PCIe expansion slot, you can transfer data to external HDDs, etc. For details on recommended third-party products, contact your local Sony representative. System Configuration Example The following are examples of network system configurations in which data is transferred between a shared file server using the unit.
Page 8
For the SR-PC4 Shared file server Switching hub SR-PC4 Web client HD monitor Overview...
[PC4] Be sure to insert the SRMemory card all the way into If the button blinks green after startup or blinks red, stop the slot. The card may not lock into place if it is not operation and contact your local Sony representative. inserted completely. b STATUS indicator h [PC4] UNLOCK button Displays the status of the unit.
g [PC5] AC IN connector Rear Connect the power cord here for connection to a power outlet. SRPC-5 h [PC5] Main power switch Use this to turn the power supply on/off. During regular 5 6 7 8 use of the unit, leave the main power switch in the on position, and use the on/standby button on the front of the unit to switch between operational mode and standby mode.
Web client Setup The web client is a PC or workstation used to operate the unit via the web application. It can also be used as a shared file server. A web browser is required (Internet Explorer, Safari, Setup Flow Firefox, etc.).
If you forget the IP address Configure the following items under NETWORK. If you forget the IP address of the unit, turn the unit off and IP ADDRESS: IP address of the unit. perform the following to restart the unit. SUBNET MASK: Subnet mask of the unit.
To unmount the server Configure the TYPE setting to select the shared disk protocol for the server to be mounted. Click the UMOUNT button on the DISK CONTROL tab screen. You can select from NFSv3, NFSv2, CIFS, or DEV. When mounting a hard drive connected to an eSATA card, select DEV.
Page 14
Item Function/settings Item Function/settings WF OVERLAY Selects the display method of the GUI TYPE Selects the size of the proxy and waveform(s). whether the jog dial appears or off: Does not display the picture. not in the GUI. Only the waveform(s) is (are) Normal Proxy without JOG Dial: displayed.
Enter a name for the cookie in the NAME box of the Item Function/settings SAVE area, and then click the SAVE button. PROXY DIR Determines the directory where the generated proxies are stored. The entered file name is automatically appended with Same as Main Files: Proxies are the date.
Lookup Table (LUT) Settings Color Control Function for the Monitor Output It is possible to load lookup table (LUT) files to the LUT banks of the unit using the web application. Color control function for the monitor output can be set The eight LUT banks provided in the unit are used to store using the web application or through control panel LUTs that are used for importing, and monitor signal...
Menu button Description Basic Operations SRPC SETUP Allows you to configure settings for the unit. Web Application Screen Allows you to configure lookup table (LUT) settings. Configuration and data transfer controls for the unit are MONITOR Allows you to configure color settings for monitor output signals.
Item Function/settings AUDIO Specifies the number of audio channels to be added to the imported files. 0CH: No audio channel is added. 2CH: Channel 1 to 2 4CH: Channel 1 to 4 6CH: Channel 1 to 6 8CH: Channel 1 to 8 10CH: Channel 1 to 10 12CH: Channel 1 to 12 14CH: Channel 1 to 14...
Page 19
Select the directory in which to store the imported file Item Function/settings in the DISK CONTROL tab screen. BASE NAME When Manual is selected for NAME SRC, this specifies the portion of the The file server directories and stored files appear at the name that will be common in all the file bottom of the screen.
Page 20
Import log display Select the check boxes for the files to be imported, and click the “Add” button. Click the Import LOG button in the DISK CONTROL tab screen to open the import log display. You can view the log The selected files are added to the CLIP LIST.
To do so, click the HOME menu button in the web Other Operations application screen, and click the REMOTE button. The IP addresses of all the web clients appear in the REMOTE tab screen. Viewing SRMemory Card Information When you click the SRPC SETUP menu button in the web application screen and click the SRMEMORY tab, media information on the SRMemory card inserted in the unit's SRMemory slot is displayed, in addition to a list of files...
Executing a job file Automatic Execution Using a Job In the QUEUE box, select the job file that you want to File execute, and then click the EXEC button. The contents of the selected job file are automatically Operations such as importing can be automatically carried executed.
SMPTE-292M/372M, BTA-S004B) • Always make a test recording, and verify that it was 3G SDI (2.97 Gbps) (SMPTE-424M) recorded successfully. SONY WILL NOT BE LIABLE FOR DAMAGES OF I/O connectors ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON...
SR-PC4 Appendix General Power supply 19.5 V Error/Warning Messages Currnet consumption 5 A (with all options installed) Operating temperature When an abnormality is detected on the unit, a yellow 5 °C to 35 °C (41 °F to 95 °F) warning mark ( ) flashes to the left of the timecode (or Storage temperature picture ID) in the MEM CONTROL window.
Warning messages Note Code Message Description After you start the salvaging process, the process EPR PLD1 [PC5] A PLD1 temperature cannot be stopped. Be sure that you have enough time TEMPERATURE error was detected for the to wait for the process to complete before starting. HIGH EPR-3 board.
Category Function # Comment Importing Ctrl+\ Previews the selected clip. LUT: 1 1024 operations Ctrl+A Adds the selected sequence # (Line No,) Output value to the import list. Ctrl+C Starts importing. Cancels importing. Shift+ Selects all files. double-click • Crtl+ Clears selection of all files.
LUT file type 5: R, G, and B have individual values L2050 (individual curves) and are aligned horizontally L2051 The bit depth is not indicated in the header. It is automatically determined by number of lines and their • values. •...
Please contact MPEG LA for any further information. MPEG LA, L.L.C., 250 STEELE STREET, SUITE 300, DENVER, COLORADO 80206, http://www.mpegla.com Job File Samples Samples of job files used for automatic execution are shown below. You can copy these samples and edit them as necessary on an external editor to create your own job files. A comment (<!-- xxxxx -->) is indicated below each element as an explanation of the element.
Page 30
The material contained in this manual consists of information Trademarks that is the property of Sony Corporation and is intended solely • Windows and Internet Explorer are registered trademarks of for use by the purchasers of the equipment described in this Microsoft Corporation in the United States and/or other manual.