OPERATING MANUAL AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE Indoor Unit ABT18LB ABT24LB Outdoor Unit AOT18LM AOT24LM KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9374319015...
CONTENTS SAFETY PRECAUTIONS ........1 ADJUSTING THE DIRECTION OF FEATURES AND FUNCTIONS ......2 AIR CIRCULATION ..........10 NAME OF PARTS ........... 3 SWING OPERATION ..........11 PREPARATION ............5 CLEANING AND CARE ........12 OPERATION ............6 SELECTING THE REMOTE CONTROL UNIT TIMER OPERATION ..........
FEATURES AND FUNCTIONS AUTOMATIC OPERATION ● COOLING MODEL Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room. ●...
NAME OF PARTS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 6 Fig. 5...
Page 5
Fig. 1 Indoor Unit Fig. 4 Remote Control Unit 1 Operating Control Panel (Fig. 2) C SLEEP button 2 MANUAL AUTO button D MASTER CONTROL button 3 Remote Control Signal Receiver E SET TEMP./SET TIME buttons ( 4 OPERATION Indicator Lamp (red) F Signal Transmitter 5 TIMER Indicator Lamp (green) G TIMER button...
PREPARATION CAUTION! Load Batteries (R03/LR03 × 2) ● Take care to prevent infants from accidentally swallowing batteries. Press and slide the battery compartment lid on the re- ● When not using the remote control unit verse side to open it. for an extended period, remove the batteries to avoid possible leakage and Slide in the direction of the arrow while pressing the...
OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Select Mode Operation Press the START/STOP button. The indoor unit’s OPERATION indicator lamp (red) will light. The air conditioner will start operating. Press the MASTER CONTROL button to select the de- sired mode.
Page 8
OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). About Mode Operation AUTO: COOLING MODEL ● When the room temperature is 2 °C higher than the set temperature, the mode will Cooling Operation switch between Cooling and Drying.
TIMER OPERATION Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5). To Use the ON timer or OFF timer To Cancel the Timer Press the START/STOP button Use the TIMER button to select “TIMER (if the unit is already operating, proceed to step 2).
SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER button to select “TIMER SLEEP button.
ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Vertical (up-down) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION VERTICAL SET button. Horizontal (right-left) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION HORIZONTAL SET button.
SWING OPERATION Begin air conditioner operation before performing this procedure. To select Vertical airflow SWING Operation Press the AIR FLOW DIRECTION VERTICAL SWING button. The SWING indicator lamp (VERTICAL SWING) (orange) will light. In this mode, the UP/DOWN air direction flaps will swing automatically to direct the air flow both up and down.
CLEANING AND CARE ● Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cord. CAUTION! ● Be sure the intake grille is installed securely. ● When removing and replacing the air filters, be sure not to touch the heat exchanger, as personal injury may result.
SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE When two or more air conditioners are installed in a room and the remote control unit is operating an air conditioner other than the one you wish to set, change the signal code of the remote control unit to operate only the air conditioner you wish to set (four selections possible).
TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the WARNING! power supply plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Symptom Items to check See Page ● Has there been a power failure? CHECK ONCE Doesn’t operate at all: — MORE ● Has a fuse blown out, or a circuit breaker been tripped? ●...
OPERATING TIPS AUTO Restart In Event of Power Interruption ● Should the power supply to the air conditioner be inter- ● Use of other electrical appliances (electric shaver, etc.) or rupted by a power failure, the air conditioner will restart nearby use of a wireless radio transmitter may cause the automatically in the previously selected mode once the air conditioner to malfunction.
OPERATING TIPS Notice Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). *● During use of the heating mode, the outdoor unit will *● During use of the heating mode, the top of the indoor occasionally commence the defrost operation for brief unit may become warm, but this is due to the fact that periods.