hit counter script
Sony Trinitron CPD-E200 Service Manual

Sony Trinitron CPD-E200 Service Manual

Trinitron color monitor
Hide thumbs Also See for Trinitron CPD-E200:

Advertisement

SERVICE MANUAL

Picture tube
Video image area
Resolution
Standard image area
Input signal
MICROFILM
http://cxema.ru
0.244-0.250 mm aperture grill pitch
17 inches measured diagonally
90-degree deflection
(16" maximum viewing image)
Approx. 328 X 242 mm (w/h)
(14
1/4
x 9
5//8
inches)
Horizontal: Max. 1600 dots
Vertical: Max. 1200 lines
Approx. 312 x 234 mm (w/h)
(12
1/4
x 9
1/4
inches)
Video
Analog RGB (75 ohms typical)
±
0.7 Vp-p,
5%, Positive
Sync
Separate HD/VD,
TTL Polarity Free
External Composite,
TTL Polarity Free (2K ohms impedance)
D99C
SPECIFICATIONS
Deflection frequency
AC input voltage / current
Dimensions
Mass
Plug and Play
Design and specifications are subject to change without notice.
®
TRINITRON
CPD-E200
US Model
Canadian Model
Chassis No. SCC-L31A-A
CHASSIS
Horizontal: 30 to 85 KHz
Vertical: 48 to 120 Hz
100 to 120 V, 50/60 Hz, 1.7A
220 to 240V, 50/60Hz, 0.9A
404 x 414 x 420mm (w/h/d)
(15
15/16
x 16
3/8
Approx. 18.8 kg (41 lb 7 oz.)
DDC/DDC2B, DDC2Bi, GTF

COLOR MONITOR

CPD-E200
x 16
1/2
inches)

Advertisement

Table of Contents
loading

Summary of Contents for Sony Trinitron CPD-E200

  • Page 1: Service Manual

    CPD-E200 SERVICE MANUAL CPD-E200 US Model Canadian Model Chassis No. SCC-L31A-A D99C CHASSIS SPECIFICATIONS Picture tube 0.244-0.250 mm aperture grill pitch Deflection frequency Horizontal: 30 to 85 KHz 17 inches measured diagonally Vertical: 48 to 120 Hz 90-degree deflection AC input voltage / current 100 to 120 V, 50/60 Hz, 1.7A...
  • Page 2: Power Management

    CPD-E200 POWER MANAGEMENT The power saving mode complies with the VESA Display Power Management Signaling standard. Each state of power management shall be activated by the host computer terminating the appropriate sync signals. Blanking the video must precede termination of the sync signals. The elapsed time counter shall also be controlled by the host computer.
  • Page 3: Table Of Contents

    CPD-E200 TABLE OF CONTENTS Section Title Page Safety Check Out Instructions ............... 4 1. GENERAL .................. 5 2. DISASSEMBLY 2-1. Cabinet Removal ............13 2-2. Service Position ............13 2-3. A and D Board Removal ..........13 2-4. Picture Tube Removal ..........14 3.
  • Page 4: Safety Check Out Instructions

    POUR SECURITE (0.75 V) FONCTIONNEMENT. NE LES REMPLACER QUE PAR DES COMPOSANTS SONY DONT LE NUMERO DE PIECE EST INDIQUE DANS LE PRESENT MANUEL OU DANS DES SUPPLEMENTS PUBLIES PAR SONY. LES REGLAGES DE Earth Ground CIRCUIT DONT L'IMPORTANCE EST CRITIQUE POUR LA SECURITE DU FONCTIONNEMENT SONT IDENTIFIES DANS LE PRESENT MANUEL.
  • Page 5 CPD-E200 — 5 — http://cxema.ru...
  • Page 6 CPD-E200 — 6 — http://cxema.ru...
  • Page 7 CPD-E200 — 7 — http://cxema.ru...
  • Page 8 CPD-E200 — 8 — http://cxema.ru...
  • Page 9 CPD-E200 — 9 — http://cxema.ru...
  • Page 10 CPD-E200 — 10 — http://cxema.ru...
  • Page 11 CPD-E200 — 11 — http://cxema.ru...
  • Page 12: Disassembly

    CPD-E200 SECTION 2 DISASSEMBLY 2-1. CABINET REMOVAL 2-2. SERVICE POSITION Two claws PUSH Cabinet A board PUSH D board 1 When the D-board is Two screws placed in service position, the Safety Earth (BVTP 4 x 16) Wire (green and yellow wire) is disconnected.
  • Page 13: Picture Tube Removal

    CPD-E200 2-4. PICTURE TUBE REMOVAL Demagnetization coil WARNING: BEFORE REMOVING Two screws THE ANODE CAP (BVTP 4 x 16) High voltage remains in the CRT even Tension spring after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove the anode A board cap.
  • Page 14: Safety Related Adjustments

    CPD-E200 SECTION 3 SAFETY RELATED ADJUSTMENTS When replacing parts shown in the table below, the 8) After adjusting the High Voltage within specification, following operational checks must be performed as a put the RV cover on RV501 as shown below and apply sufficient amount of RTV around RV501.
  • Page 15: Adjustments

    CPD-E200 SECTION 4 ADJUSTMENTS Connect the communication cable of the connector located on the D board on the monitor. Run the service software and then follow the instructions. 1-690-391-21 A-1500-819-A 3-702-691-01 Interface Unit Connector Attachment IBM AT Computer To BUS CONNECTOR...
  • Page 16 CPD-E200 4. Display crosshatch pattern with red and blue lines and TLV movement black field. 5. Adjust H.STAT and V.STAT with 4 pole magnet. Use 4 pole magnet, not "HSTAT" and "VSTAT". 4 Pole Magnet 15. If necessary, repeat steps 3-14 to make the optimum condition for the entire screen.
  • Page 17 CPD-E200 Vertical Convergence 4-7. Digital Convergence Adjustment Convergence (Low) Mode YBH-T-HI CBH-T-R-LHI 1. Adjust the H.STAT and V.STAT with "HSTAT" and CBH-T-L-HI "VSTAT". MBH-T-R-HI MBH-T-L-HI A. Horizontal Convergence APH-R-HI APH-L-HI HSTAT-HI YBH-T-LO MBH-B-R-HI MBH-B-L-HI CBH-T-R-LO CBH-T-L-LO CBH-B-R-HI CBH-B-L-HI MBH-T-R-LO MBH-T-L-LO...
  • Page 18 http://cxema.ru...
  • Page 19 http://cxema.ru...
  • Page 20 http://cxema.ru...
  • Page 21 http://cxema.ru...
  • Page 22: Semiconductors

    CPD-E200 5-4. SEMICONDUCTORS REF.NO. 2SC2610 PART NO. DESCRIPTION REMARK REF.NO. PART NO. DESCRIPTION 2SC1623-L5L6 REMARK DTC143ESA 2SC4634LS-CB11 2SA1037AK-T146-R 2SC3941A-Q(TA) DTA114EKA-T146 HZU5.6B2TRF MTZJ-T-77-12B D1NS6 2SK2605LBSONY 2SA1175-HFE ERC81-004 D1NL40-TA2 2SK3155-01 2SC2785-HFE EGP10D UF4007G23 2SK2098-01MR-F119 DTC114TSA RGP10JPKG23 RGP02-20EL-6394 2SK2843LBS2SONY 2SC3311A-QRSTA RGP10DG23 ERB91-02 IRFU110A...
  • Page 23: Exploded Views

    CPD-E200 SECTION 6 EXPLODED VIEWS Note: • • Items with no part number and no descrip- Items marked " " are not stocked tion are not stocked because they are sel- since they are seldom required for routine The components identified by shading dom required for routine service.
  • Page 24: Packing Materials

    CPD-E200 6-2. PACKING MATERIALS REF.NO. PART NO. DESCRIPTION REMARK REF.NO. PART NO. DESCRIPTION REMARK REF.NO. PART NO. DESCRIPTION REMARK * 3-867-254-11 MANUAL, INSTRUCTION * 4-070-972-01 CUSHION (UPPER) (ASSY) 1-790-568-11 CORD, POWER * 4-041-927-11 BAG, POLYETHYLENE * 4-070-969-01 CUSHION (LOWER) (ASSY) * 4-070-977-01 INDIVIDUAL CARTON —...
  • Page 25 CPD-E200 NOTES: — 36 — http://cxema.ru...
  • Page 26: Electrical Parts List

    CPD-E200 SECTION 7 ELECTRICAL PARTS LIST The components identified by [ in this manual RESISTORS Note: have been carefully factory-selected for each • All resistors are in ohms set in order to satisfy regulations regarding X- REF.NO. The components identified by shading PART NO.
  • Page 27 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame et une marque and mark ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ sont critiques pour la securite. Ne les remplacer are critical for safety.
  • Page 28 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame and mark ¡ ¡ ¡ ¡ ¡ et une marque ¡ ¡ ¡ ¡ ¡ sont critiques pour la are critical for safety. Replace only with part number specified.
  • Page 29 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame et une marque and mark ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ sont critiques pour la securite. Ne les remplacer are critical for safety.
  • Page 30 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame et une marque and mark ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ sont critiques pour la securite. Ne les remplacer are critical for safety.
  • Page 31 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame et une marque and mark ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ sont critiques pour la securite. Ne les remplacer are critical for safety.
  • Page 32 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame et une marque and mark ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ sont critiques pour la securite. Ne les remplacer are critical for safety.
  • Page 33 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame et une marque and mark ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ sont critiques pour la securite. Ne les remplacer are critical for safety.
  • Page 34 CPD-E200 Note: Note: The components identified by shading Les composants identifies per un trame et une marque and mark ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ sont critiques pour la securite. Ne les remplacer are critical for safety.
  • Page 35 CPD-E200 Note: Note: The components identified by [ [ [ [ [ in this manual have been The components identified by shading carefully factory-selected for each set in order to satisfy and mark ¡ ¡ ¡ ¡ ¡ are critical for safety.
  • Page 36 CPD-E200 REF.NO. PART NO. DESCRIPTION REMARK REF.NO. PART NO. DESCRIPTION REMARK R805 1-247-807-31 CARBON 1/4W R806 1-247-807-31 CARBON 1/4W R807 1-249-411-11 CARBON 1/4W R808 1-249-413-11 CARBON 1/4W SWITCH S801 1-771-734-11 SWITCH, TACTILE MISCELLANEOUS 1-419-092-11 COIL, DEGAUSSING 1-452-923-41 NECK ASSEMBLY (NA2915)
  • Page 37 CPD-E200 NOTES: REF. NO. PART NO. DESCRIPTION REMARK REF. NO. PART NO. DESCRIPTION REMARK — 48 — http://cxema.ru...
  • Page 38 http://cxema.ru...
  • Page 39 Sony Corporation English Sony Technology Center 99FT74182-1 Product Quality Division Printed in U.S.A. 9-978-850-01 © 1999.06 Service Promotion Department http://cxema.ru...

Table of Contents