Sign In
Upload
Manuals
Brands
ABB Manuals
Relays
RELION REF610
ABB RELION REF610 Manuals
Manuals and User Guides for ABB RELION REF610. We have
5
ABB RELION REF610 manuals available for free PDF download: Technical Reference Manual, Operator's Manual, Product Manual
ABB RELION REF610 Technical Reference Manual (177 pages)
Feeder Protection Relay
Brand:
ABB
| Category:
Relays
| Size: 1.02 MB
Table of Contents
Table of Contents
3
Copyrights
7
1 Introduction
9
Use of Symbols
9
Intended Audience
9
This Manual
9
Product Documentation
10
Document Conventions
10
REF610 Product Documentation
10
Document Revisions
11
2 Safety Information
13
3 Product Overview
15
Use of the Relay
15
Features
15
4 Application
17
Requirements
17
Environmental Conditions
17
Configuration
17
Technical Reference Manual - ANSI Version
18
5 Technical Description
21
Product Functions
21
Protection Functions
21
IEC Symbols and IEEE Device Numbers
21
Functional Description
21
Inputs
21
Outputs
22
Disturbance Recorder
22
Front Panel
22
Non-Volatile Memory
23
Self-Supervision
23
Permanent IRF
23
Warning with Text Message
23
Time Synchronization
24
Warning with Numeric Code
24
Measurements
25
Measured Values
25
Configuration
25
Signal Diagram
26
Block Diagram
27
Overcurrent Protection
27
Ground-Fault Protection
29
Thermal Protection for Cables
30
Thermal Level at Constant Currents
31
Trip Curves When no Prior Load
33
Trip Curves at Prior Load 0.7 X FLA
34
Trip Curves at Prior Load I X FLA
35
Circuit-Breaker Failure Protection
36
Phase Discontinuity Protection
36
Arc Protection
37
Auto-Reclose Function
38
Block Diagram of the Arc Protection
38
Shot Initiation
40
Simplified Shot Logic Diagram
40
Blocking of Shot Initiation
41
Simplified Shot Initiation Logic Diagram
41
Disable of the Auto-Reclose Function
42
Blocking of Protection Elements
43
Circuit-Breaker Closing
43
Information on the Circuit-Breaker Position
43
Definite Trip Alarm
44
Inverse Definite Minimum Time Characteristics
44
Lockout of the Auto-Reclose Function
44
Technical Reference Manual - ANSI Version
44
IDMT Characteristics According to IEC 60255-3
45
Time/Current Characteristic Settings
45
Values of Constants Α and Β
45
Operate Time Tolerances Specified by the Standard
46
Normal Inverse-Time Characteristic
47
Very Inverse-Time Characteristic
48
Extremely Inverse-Time Characteristic
49
Long-Time Inverse-Time Characteristic
50
IDMT Characteristics According to the IEEE C37.112
51
Values of Constants A, B and P
51
RI-Type Characteristic
55
RD-Type Characteristic (RXIDG)
57
RD-Type Inverse-Time Characteristic
58
Settings
58
Setting Values
59
Example of Calculating the Checksum of a SG_ Selector Switchgroup
60
Switchgroups and Parameter Masks
60
Sgf1
61
Sgf2
61
Sgf3
62
Sgf4
62
Sgf5
62
Sgb1...Sgb5
63
Sgr1...Sgr8
64
Output Signal Matrix
65
Sgl1...Sgl8
66
Auto-Reclose SG1...SG3
67
Memory Settings
68
New Trip Target Timer
68
Non-Volatile Memory Settings
68
Technical Data on Protection Functions
69
Elements 51P, 50P-1 and 50P-2
69
Elements 51N and 50N
70
Element 46
71
Element 49
71
Element ARC and L>
72
Relative Sensitivity of Lens Sensors
72
Cbfail
73
Trip-Circuit Supervision
73
Recommended Values for Rext
74
Trip Lockout Function
75
Trip Counters for Circuit-Breaker Condition Monitoring
76
Target Leds and Operation Target Messages
76
Demand Values
76
Commissioning Tests
77
Function
77
Disturbance Recorder
77
Disturbance Recorder Data
78
Sampling Frequency
78
Control and Target of Disturbance Recorder Status
79
Triggering
79
Settings and Unloading
79
Event Code of the Disturbance Recorder
80
Recorded Data of the Last Events
80
Communication Ports
82
Front Connection for Local Communication
83
IEC 60870-5-103 Remote Communication Protocol
83
Information Mapping of Configuration Set 1 and 2
85
Modbus Remote Communication Protocol
87
ASCII Character Format
88
Profile of Modbus
88
RTU Character Format
88
Supported Application Functions
89
Supported Diagnostic Subfunctions
89
Diagnostic Counters
90
Fault Records
91
Possible Exception Codes
91
User-Defined Registers
91
Event Records
92
Selection Code 2: the Master Reads the Oldest Stored Record
92
To Read a Fault Record
92
Selection Code 1: Reading the Oldest Unread Record
93
Selection Code 2: Reading the Oldest Stored Record
93
Change Detection Bit
94
Digital Inputs
94
Mapping of Modbus Data: User-Defined Registers
95
Modbus Data Mapping
95
Mapping of Modbus Data: Analog Data
96
Mapping of Modbus Data: Digital Data
96
Mapping of Modbus Data: Additional Analog Data
99
Mapping of Modbus Data: Real-Time Clock
99
Mapping of Modbus Data: Recorded Data
99
Mapping of Modbus Data: Relay Identification
99
Status Registers
100
Event Record
102
Real-Time Clock Structure
102
DNP 3.0 Remote Communication Protocol
102
Protocol Parameters
103
Storing DNP 3.0 Parameters
103
DNP 3.0 Point List
103
Binary Data
104
DNP 3.0 Device Profile
106
Supported Function Codes
108
Supported Objects
109
Specific DNP Features
113
Unsolicited Reporting Pick up
113
Collision Avoidance and Detection
114
DNP Counters and Frozen Counters
114
Event Buffer Overflow
114
Event Handling
114
Scaling DNP Analog Values
115
DNP Analog Values Deadband
116
SPA Bus Communication Protocol Parameters
116
Auto-Reclose Parameters
118
Recorded Data
119
Recorded Data: Channels 1...5
121
Parameters for the Disturbance Recorder
123
Control Parameters
124
Disturbance Recorder External Triggering and Storing
124
Disturbance Recorder Internal Triggering and Storing
124
Input Signals
126
Output Signals
127
Parameters for IEC 60870-5-103 Remote Communication Protocol
129
Parameters for Modbus Remote Communication Protocol
129
Parameters for DNP 3.0 Remote Communication Protocol
130
Event Codes
131
Event Codes E1...E4 and E7
132
Event Codes E31...E36
132
Event Codes E50...E51
132
Event Masks
132
Event Codes E1...E12
133
Event Codes E13...E24
133
Event Codes E1...E16
134
Event Codes E25...E42
134
Event Codes E17...E26
135
Self-Supervision (IRF) System
136
Internal Relay Fault
136
IRF Codes
137
Warnings
137
Warning Codes
138
Relay Parameterization
138
Local Parameterization
138
External Parameterization
138
Design Description
138
Input/Output Connections
138
Auxiliary Supply Voltage
144
IRF Contact
144
Output Contacts
144
Light Sensor Input Connections
145
Serial Communication Connections
145
Plastic Fibre-Optic Connection
146
RS-485 Connection
146
Jumper Location on the RS-485 Communication Module
147
RS-485 Rear Connector
147
Combined Fibre-Optic Connection (Plastic and Glass)
148
Jumper Location on Communication Module for Plastic and Glass Fibre
148
Receiver Selection
148
Transmitter Selection
148
Fibre-Optic Rear Connectors (Plastic and Glass)
149
RS-485 Rear Connector (DNP 3.0)
150
Jumper Location on the DNP 3.0 Communication Module
151
Technical Data
151
Power Supply
151
Energizing Inputs
152
Measuring Range
152
Lens Sensor and Optic Fibre for Arc Protection
153
Non-Trip Output SO1 and Optional SO4 and SO5
153
Non-Trip Output SO2, Optional SO3, and IRF Output
153
Trip Outputs (PO1, PO2, PO3)
153
Electromagnetic Compatibility Tests
154
Environmental Tests and Conditions
154
Data Communication
155
Optional Communication Modules and Protocols
155
Standard Tests
155
Auxiliary Voltage
156
6 Application Examples
157
Fast Initiation of Shot 1 Using One Fast and One Delayed Element
157
Auto-Reclose Function
157
Fast Tripping and Initiation of Shot 1 Using Two Protection Elements
157
Fast Initiation of Shot 1 Using Start Signals
158
Fast Tripping and Initiation of Shot 1 Using Pickup Signals
158
If One or Several Phase Currents
159
Selecting Adaptive Sequence Length
159
Arc Protection with One REF610 Relay
160
Arc Protection with One REF610
161
Arc Protection with Several REF610 Relays
161
Arc Protection with Several REF610 Relays and One REA101
162
Arc Protection with REF610 and REA101
163
7 Ordering Information
165
Ordering Key for Complete Relays
165
Ordering Key for Spare Units
166
8 Check Lists
167
Setting Group 1
167
9 Abbreviations
173
Advertisement
ABB RELION REF610 Technical Reference Manual (172 pages)
Feeder Protection Relay
Brand:
ABB
| Category:
Other
| Size: 0.89 MB
Table of Contents
Table of Contents
3
1 Introduction
9
This Manual
9
Use of Symbols
9
Intended Audience
9
Product Documentation
10
Document Conventions
10
Document Revisions
10
2 Safety Information
11
3 Product Overview
13
Use of the Relay
13
Features
13
4 Application
15
Requirements
15
Configuration
15
5 Technical Description
19
Functional Description
19
Product Functions
19
Protection Functions
19
Inputs
19
Outputs
20
Disturbance Recorder
20
Front Panel
20
Non-Volatile Memory
21
Self-Supervision
21
Time Synchronization
22
Measurements
23
Configuration
23
Block Diagram
25
Overcurrent Protection
25
Earth-Fault Protection
27
Thermal Protection for Cables
28
Phase Discontinuity Protection
33
Circuit-Breaker Failure Protection
33
Arc Protection
34
Auto-Reclose Function
35
Inverse Definite Minimum Time Characteristics
41
Settings
55
Technical Data on Protection Functions
66
Trip-Circuit Supervision
70
Trip Lockout Function
72
Trip Counters for Circuit-Breaker Condition Monitoring
73
Indicator Leds and Operation Indication Messages
73
Demand Values
73
Commissioning Tests
74
Disturbance Recorder
74
Function
74
Disturbance Recorder Data
75
Control and Indication of Disturbance Recorder Status
76
Triggering
76
Settings and Unloading
76
Event Code of the Disturbance Recorder
77
Recorded Data of the Last Events
77
Communication Ports
79
IEC 60870-5-103 Remote Communication Protocol
80
Modbus Remote Communication Protocol
84
Profile of Modbus
85
DNP 3.0 Remote Communication Protocol
99
Protocol Parameters
100
DNP 3.0 Point List
100
DNP 3.0 Device Profile
103
Specific DNP Features
110
SPA Bus Communication Protocol Parameters
113
Event Codes
128
Self-Supervision (IRF) System
132
Relay Parameterization
134
Design Description
135
Input/Output Connections
135
Light Sensor Input Connections
141
Serial Communication Connections
141
Technical Data
147
6 Application Examples
153
Auto-Reclose Function
153
Fast Tripping and Initiation of Shot 1 Using Two Protection Stages
153
Fast Tripping and Initiation of Shot 1 Using Start Signals
154
Selecting Adaptive Sequence Length
155
Arc Protection
156
Arc Protection with One REF 610 Relay
156
Arc Protection with Several REF 610 Relays
157
Arc Protection with Several REF 610 Relays and One REA 101
158
7 Ordering Information
161
8 Check Lists
163
9 Abbreviations
169
ABB RELION REF610 Technical Reference Manual (158 pages)
Feeder Protection Relay
Brand:
ABB
| Category:
Relays
| Size: 1.1 MB
Table of Contents
Table of Contents
3
1 Introduction
6
About this Manual
6
The Use of the Relay
6
Features
6
Warranty
8
Revision History
8
2 Safety Information
9
3 Instructions
10
Application
10
Requirements
10
Configuration
10
4 Technical Description
13
Functional Description
13
Product Functions
13
Protection Functions
13
Inputs
13
Outputs
14
Disturbance Recorder
14
Hmi
14
Non-Volatile Memory
14
Self-Supervision
14
Time Synchronization
15
Measurements
16
Configuration
16
Protection
18
Block Diagram
18
Overcurrent Protection
19
Ground-Fault Protection
20
Thermal Protection for Cables
21
Phase Discontinuity Protection
26
Circuit-Breaker Failure Protection
26
Arc Protection
27
Auto-Reclose Function
28
Inverse Definite Minimum Time Characteristics
34
10.Settings
46
11.Technical Data on Protection Functions
58
Trip-Circuit Supervision
63
Trip Lockout Function
64
Trip Counters for Circuit-Breaker Condition Monitoring
65
Indicator Leds and Operation Target Messages
65
Demand Values
65
Commissioning Tests
66
Disturbance Recorder
66
1.Function
66
2.Disturbance Recorder Data
66
3.Control and Target of Disturbance Recorder Status
67
4.Triggering
68
5.Settings and Unloading
68
6.Event Code of the Disturbance Recorder
68
Recorded Data of the Last Events
68
Communication Ports
70
IEC 60870-5-103 Remote Communication Protocol
71
REF 610 Feeder Protection Relay 1MRS
72
Modbus Remote Communication Protocol
75
1.Protocol Overview
75
2.Profile of Modbus REF 610
76
DNP 3.0 Remote Communication Protocol
89
1.Protocol Overview
89
2.Protocol Parameters of REF 610
89
3.DNP 3.0 Point List of REF 610
89
4.DNP 3.0 Device Profile of REF 610
93
5.REF 610-Specific DNP Features
100
SPA Bus Communication Protocol Parameters
103
1Mrs 755535 Ref
105
Channel 2 Setting Range
105
Variable Settings (R), Channel
105
Channel
107
Pickup Value of Element 0.50
110
Pickup Value of Element 51P S1
110
1.Event Codes
118
Self-Supervision (IRF) System
122
Relay Parameterization
123
Design Description
124
Input/Output Connections
124
Light Sensor Input Connections
129
Serial Communication Connections
129
Technical Data
134
5 Application Examples
139
Auto-Reclose Function
139
Fast Tripping and Initiation of Shot 1 Using Two
139
Protection Stages
139
Fast Tripping and Initiation of Shot 1 Using Pickup Signals
140
Selecting Adaptive Sequence Length
141
Arc Protection
142
Arc Protection with One REF 610 Relay
142
Arc Protection with Several REF 610 Relays
144
Arc Protection with Several REF 610 Relays and One REA 101
145
6 Ordering Information
146
7 Revision History of REF 610
148
Revision Identification
148
Changes and Additions to Earlier Released Revision a
148
8 References
149
9 Abbreviations
150
10 Check Lists
152
Advertisement
ABB RELION REF610 Operator's Manual (50 pages)
Feeder Protection Relay ANSI Version
Brand:
ABB
| Category:
Relays
| Size: 0.96 MB
Table of Contents
Table of Contents
3
1 Introduction
5
About this Manual
5
The Use of the Relay
5
Features
5
Warranty
7
Revision History
7
2 Safety Information
8
3 Instructions
9
HMI Features
9
Front Panel
9
Display
9
Display Test at Power up
9
Display Modes
10
Display Backlight
10
How to Adjust the Display Contrast
10
How to Use the Push Buttons
11
Main Menu
12
Submenu
12
HMI Password
12
SPA Password
14
How to Select Language
14
How to Set the Real-Time Clock
15
How to Reset the Trip Lockout Function
16
How to Switch between Front and Rear Connection
17
1.Target LED for Front Communication
18
How to Select the Protocol for Rear Communication
18
HMI Operation Levels
19
User Level
19
Menu Groups of the User Level
19
How to Monitor Measured Values
19
How to Monitor Recorded Data
20
Info
21
Technical Level
22
Menu System of Parameters
22
How to Change Settings
22
Configuration
26
How to Acknowledge and Reset Targets, Output Contacts and Memorized Values
28
Protection Relay Targets
28
Target Leds
29
Green Target LED
29
Yellow Target LED
29
Red Target LED
30
Programmable Target Leds
30
Target Messages
30
Operation Target Messages
31
Disturbance Recorder Target
32
Targets for Internal Relay Faults (Irfs) and Warnings
32
Detachable Plug-In Unit
35
Identifying the Product
35
Detaching and Installing the Plug-In Unit
36
Inserting and Changing the Battery
37
REF 610 Feeder Protection Relay 1MRS
38
4 Commissioning and Maintenance
39
Commissioning Instructions
39
Maintenance Instructions
40
Relay Verification
40
Preventive Parts Replacement
41
Measurements Verification
41
Function Test
41
Digital Input Test
42
Arc Detection Test
42
Testing of Protection Functions
43
Testing of the Short-Circuit Protection
43
Testing of the Ground-Fault Protection
44
5 Spare Parts
45
Plug-In Unit
45
Battery
45
6 Repair
46
7 Ordering Information
47
8 References
48
9 Abbreviations
49
ABB RELION REF610 Product Manual (28 pages)
Feeder Protection
Brand:
ABB
| Category:
Protection Device
| Size: 2.25 MB
Table of Contents
Table of Contents
2
Description
3
Functional Overview
3
Protection Functions
4
Application
5
Measurement
6
Disturbance Recorder
6
Event Recorder
7
Circuit-Breaker Monitoring
7
Trip-Circuit Supervision
7
Self-Supervision
7
Inputs/Outputs
7
Communication
7
Technical Data
9
Mounting Methods
19
Relay Case and Plug-In Unit
19
Selection and Ordering Data
19
Accessories
21
Tools
22
Terminal Diagram
24
Approvals
25
Certificates
25
References
25
Functions, Codes and Symbols
25
Document Revision History
26
Advertisement
Related Products
ABB REF 610
ABB REF615 E
ABB REF615 F
ABB REF615 J
ABB REF615 L
ABB REF615 M
ABB REF615 A
ABB REF615 B
ABB REF615 K
ABB REF615 G
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL