Manuals and User Guides for HP 5890 Series II. We have
2
HP 5890 Series II manuals available for free PDF download: Service Manual, Reference Manual
HP 5890 Series II Reference Manual (244 pages)
Hewlett-Packard Reference Manual
Brand:
HP
| Category:
Laboratory Equipment
| Size: 2.18 MB
Table of Contents
Table of Contents
3
Chapter 1 - Columns and Fittings
9
Column Oven
11
Column Placement
12
Packed Column
12
Hewlett-Packard Capillary Columns
13
Fittings
14
Liners/Adapters and Inserts, General
17
Inlet/Detector Liners/Adapters
20
Packed Column Inlet Liners
20
Detector Liners/Adapters
22
ECD and TCD Adapters
23
Liner/Adapter Installation
24
Inlet Inserts
25
Packed Column Inlet Inserts
25
Split/Splitless or Split-Only Capillary Inlet Inserts
27
Jet Replacement, Fids or Npds
30
Metal Capillary Columns
30
Chapter 2 - Keyboard and Displays
31
Displaying Setpoints
33
Entering Setpoints
34
Keyboard Operation, INET Control
37
Protecting Setpoints
38
Loading Default Setpoints
39
Chapter 3 - Temperature Control
43
Temperature Control
44
Valid Setpoint Ranges
46
Cryogenic (Sub-Ambient) Oven Control
47
Programming Oven Temperature
49
Oven Status
50
Oven Safety
51
Fault: Messages
52
After a Power Failure
53
Oven Temperature Calibration
54
Chapter 4 - Electronic Flow Sensing
57
Displaying Gas Flow Rate
58
Designating Gas Type
59
Electronic Flow Sensor (EFS) Calibration
60
Preparation
61
Setting the Zero Calibration Value
61
Setting the GAIN Calibration Value
63
Entering Specific ZERO and GAIN Values
65
Chapter 5 - Signal Output
67
Zeroing Signal Output
68
Displaying Current Setpoint
69
Self• Setpoint
70
User•Defined Setpoint
72
Signal Attenuation
72
Displaying Current
75
Range
75
Attn
75
Setpoints
75
Entering / Setpoints
76
Switching off the +1 MV Output
76
Test Signal Output
77
Instrument Network (INET)
79
The Controller
79
An Instrument
81
Active Workspace
82
HP 5890 INET States
82
INET Operation
83
Automatic INET Reconfiguration
85
INET Configuration
85
Switching between Global and Local
86
INET/HP-IL Addresses
87
HP-IL Loopback Test
90
Warn: and Fault: Messages
92
File Compatibility with Data Handling Devices
94
What Are the Modes
94
What Is the Proper Mode for My Data Handling Device
94
How Do I Know in Which Mode My GC Is Configured Now
94
How Do I Change Modes
95
How to Convert HP 339X Integrator Workfiles from 5890A to SERIES II Mode
97
Chapter 6 - Inlet Systems
99
Packed Column Inlet
100
Electronic Flow Sensor
102
Septum-Purged Packed Column Inlet
103
Problems at High Inlet Temperatures
104
A Thermally Optimized High-Temperature Inlet
104
Septum Purge
105
Electronic Flow Sensor
106
Split/Splitless Capillary Inlet
107
Carrier Gas Considerations
108
Initial Column Head Pressure
110
Split Sampling
111
Splitless Sampling
114
Injection Technique, Split/Splitless Sampling
121
Chapter 7 - Detector Systems
123
Capillary Makeup Gas Flow Rate
124
FID and NPD Jets
125
Flame Ionization Detector (FID)
126
FID Flameout Problems
128
Nitrogen-Phosphorus Detector (NPD)
129
Performance Considerations
132
Electron Capture Detector (ECD)
135
Requirements for USA Owners
135
Temperature
140
Background Level
141
Thermal Conductivity Detector (TCD)
143
Optimizing Performance
146
Analyzing for Hydrogen, Special Considerations
148
TCD-To-FID Series Connection
149
Filament Passivation
149
Capillary Column Considerations
150
Flame Photometric Detector (FPD)
151
Optimizing FPD Sensitivity and Selectivity
151
Flame Ignition Problems
153
Chapter 8 - Preventive Maintenance
155
Conditioning Columns
156
(Re)Packing Columns
158
Packed Column Inlet
159
Changing Septa
159
Insert/Liner Care
160
Leaks
160
Cleaning
162
Split/Splitless Capillary Inlets
163
Changing Septa
163
Insert Care
164
Leaks
165
Cleaning
168
Liner And/Or Insert Care
169
Glass Inserts
169
Repacking a Split Insert
170
Metal Inserts And/Or Liners
171
Flame Ionization Detector (FID)
171
Jet Exchange/Replacement
172
Cleaning
173
Ignition Problems
177
Nitrogen-Phosphorus Detector (NPD)
178
Cleaning
178
Removing/Replacing the NPD Collector
181
Type B NPD Transformer/Collector Assembly
184
Reinstallation
186
Electron Capture Detector (ECD)
188
Frequency Test
188
Carrier Gas Evaluation
188
Leaks
189
Thermal Cleaning
190
Packed Column
191
Capillary Column
191
Radioactivity Leak Test (Wipe Test)
192
Thermal Conductivity Detector (TCD)
192
Cleaning
192
Flame Photometric Detector
193
Cleaning/Replacing FPD Windows, Filters, Seals
193
Cleaning/Replacing the FPD Jet
197
FPD Leak Testing (GC with Electronic Flow Sensor)
198
FPD Leak Testing (GC Without Electronic Flow Sensor)
199
Conditioning Chemical Traps
200
Chapter 9 - Chromatographic Troubleshooting
201
Introduction
202
Baseline Symptoms
202
Position
202
Wander and Drift
203
Noise
204
Spiking
206
Retention Time Symptoms
207
Retention Time Drift
207
Retention Time Wander (Reproducibility)
207
Peak Symptoms
209
No Peaks
209
Inverted Peaks
209
Extra Peaks
209
Deformed Peaks
211
Troubleshooting Valve Systems
214
Chromatographic Symptoms
214
Locating Leaks
216
Pressure Check
217
Electronic Pressure Control
218
Safety Shutdown
219
Proper Configuration
220
Switch Setting Examples
221
Chapter 10 - Test Sample Chromatograms
223
Test Sample Chromatograms
225
Index
241
Advertisement
HP
5890 SERIES II
Service Manual
HP 5890 Series II Service Manual (326 pages)
Gas Chromatograph
Brand:
HP
| Category:
Measuring Instruments
| Size: 4.72 MB
Table of Contents
Section 3
44
Table of Contents
44
Flow/Pressure Control Components
44
PCOC EPC/MPC Troubleshooting
45
Remove/Replace Inlet Flow Control Components
48
Remove/Replace Split/Splitless Capillary Inlet Solenoid Valve
50
Remove/Replace Electronic Pressure Control (EPC) Components
54
Remove/Replace Manual Pressure Control (MPC) Components
57
Remove/Replace EPC/MPC Pressure Control PCB
59
Typical Switch Settings for EPC/MPC Pcbs
61
Replace Electronic Flow Sensor Module
62
Electronic Flow Sensor (EFS) Calibration
65
Setting the ZERO Calibration Value
65
Setting the GAIN Calibration Value
66
Entering Specific ZERO and GAIN Values
67
Replacing/Repairing a Flow Manifold Block
68
Section 4
71
Detector Troubleshooting
73
Thermal Conductivity Detector (Tcd)
74
Remove/Replace TCD Detector Weldment
74
Remove/Replace TCD Solenoid Switching Valve
78
Flame Ionization Detector (Fid)
81
Remove/Replace FID Ignitor
81
Remove/Replace FID Diode Bridge Assembly
82
Remove/Replace FID Collector Body/Collector Assembly
84
Remove/Replace FID Jet
88
Remove/Replace FID Detector Weldment
91
Nitrogen- Phosphorus Detector (Npd)
98
Remove/Replace NPD Active Element Power Transformer (Toroid)
98
Remove/Replace NPD Collector
103
Remove/Replace NPD Jet
105
Svc
105
Svc
106
Remove/Replace NPD Active Element Power Control
108
Remove/Replace NPD Detector Weldment
111
Electron Capture Detector (Ecd)
118
Electron Capture Detector (Ecd) (19233A/19235A Versions) Svc
119
Remove/Replace ECD Cells Weldment And/Or Heated Block
119
(19233A/19235A Versions)
119
Electron Capture Detector (G1223A/G1224A Versions)
123
Remove/Replace ECD Cells Weldment And/Or Heated Block
123
(G1223A/G1224A Versions)
123
Clean Anode (ECD Cell Weldment) (G1223A/G1224A Versions)
126
Flame Photometric Detector (Fpd)
128
Clean/Replace Photomultiplier Tube (PMT)
128
Clean/Replace FPD Filter
131
Remove/Replace FPD Diode Bridge Assembly
133
Clean/Replace FPD Heat Shield Windows
136
Replace FPD Jet Assembly and First Heat Shield Window
140
Replace Fused Silica Liner
146
Replace Detector Base Weldment
150
Adjust High Voltage
155
Replacing a Detector Pcb
157
Remove/Replace Detector PCB
157
Section 6
192
Remove/Replace Inlet Zone Heater and Sensor Cartridges
200
Remove/Replace Packed Column Inlet Heater and Sensor Cartridgessvc
200
Svc
201
Svc
202
Svc
203
Svc
204
Svc
205
Svc
206
Svc
207
Remove/Replace PCOC Inlet Heater and Sensor Cartridges
207
Remove/Replace Detector Zone Heater and Sensor Cartridges
209
Remove/Replace TCD Heater and Sensor Cartridges
209
Remove/Replace FID Heater and Sensor Cartridges
211
Remove/Replace NPD Heater and Sensor Cartridges
215
Remove/Replace FPD Heater and Sensor Cartridges
225
Remove/Replace Valve Box Heater and Sensor Cartridges
228
Replacing TCD Delta- T Temperature Sensor Cartridges
230
Temperature Sensor Data
236
Section 7
237
Valves
238
Introduction
238
Adjustable Restrictors
241
Gas Sample Loops
241
LIQUID SAMPLE VALVES (Lsvs)
242
Troubleshooting and Maintenance
243
Chromatographic Symptoms
243
Loss of Sensitivity or Excessive Drift
243
Loss of Peaks in Specific Areas of the Chromatogram
243
Baseline Upsets
243
Extraneous Peaks
244
Locating Leaks
244
Pressure Check
244
Valve Box Assembly Removal
251
Valve Actuator Alignment
252
Valve Actuation of GC- Controlled Valves
253
Valve Configuration Diagrams
254
Advertisement
Related Products
HP 5890 Series II Plus
HP 5973 MSD
HP 5800
HP PROLIANT 580554-001
HP ProSignia 586
HP 5800-48G with 2 Slots
HP 5820AF-24XG
HP 5800-24G-PoE+
HP 581A
HP 580A
HP Categories
Desktop
Laptop
Server
Monitor
Switch
More HP Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL