hit counter script

Removing The Multi-Purpose Tray Separation Pad - Canon imageRUNNER ADVANCE 4551i Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE 4551i:
Table of Contents

Advertisement

3. Free the claw [1], slide the Shaft Support (Front) [2], and remove the Multi-purpose Tray Pickup Roller [3].
CAUTION:
When installing it, be sure to follow the order shown below.
1. Fit the hole of the Multi-purpose Tray Pickup Roller [1] onto the protrusion of the Shaft Support (Rear) [2].
2. Attach the Shaft Support (Front) [4] while pushing down the Separation Pad [3].
3. Attach the Shaft Support (Rear) [2] to the Multi-purpose Tray Pickup Roller [1].
NOTE:
When the consumable parts have been replaced, be sure to clear the parts counter shown below in service mode.
• COPIER > COUNTER > DRBL-1 > M-FD-RL

Removing the Multi-purpose Tray Separation Pad

■ Preparation
CAUTION:
Do not touch the surface of the Separation Pad during the work.
1. Remove the Multi-purpose Tray Pickup
1x
[1]
[4]
Roller."Removing the Multi-purpose Tray Pickup Roller" on page 281
[2]
[1]
283
4. Disassembly/Assembly
[2]
[3]