VIDEO PROJECTOR VPL-VW50 PROTOCOL MANUAL 1st Edition...
Page 2
Ce manual est destiné uniquement aux personnes compétentes en charge de l’entretien. Afin de réduire les risques de décharge électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. VPL-VW50...
This protocol manual describes the basic configuration and basic operations of various commands used for projector. Projector can be controlled using the commands provided in “Appendix”. Using an external CONTROLLER , etc., inputs can be switched and the power can also be turned on and off. In the follow- ing paragraphs, “CONTROLLER”...
Reception in the Master side the Master side START CODE : 0xA9 ACK / NAK DUMMY DATA CHECK SUM END CODE : 0x9A 0xA9 1010 1001 0x9A 1001 1010 Answer 1011 1011 0xBB (With Data) ITEM NUMBER REPLY DATA VPL-VW50...
GET: Unused. Set Dummy data [0x00, 0x00] Check Sum End of Command Receive results of the data transmission from the Projector. Start of Command Results correspond with the data transmission Refer to the Appendix Table 3 for the data in detail.
Pins indicated as D-Sub 25 Pin are not used. Assured cable length: 15 m (However, assurance may not be applicable for some cables.) The software for controlling the projector from a PC is intended for performing transmission and recep- tion for only the TxD and RxD lines.
. For undefined commands or commends determined as invalid by PROJECTOR, PROJECTOR will send the “NAK” return data to CONTROLLER . . Take note that when data is written when the input signal of PROJECTOR is unstable, that data (value) will not be incorporated.
User2 User3 Remarks Data Upper byte Lower byte Set/Get 00h to 64h (0 to 100) 00h to 64h (0 to 100) 00h to 64h (0 to 100) 00h to 64h (0 to 100) 00h to 64h (0 to 100) VPL-VW50...
Page 11
Input-A Signal Sel Color Space USER GAIN RED USER GAIN GREEN USER GAIN BLUE USER BIAS RED USER BIAS GREEN USER BIAS BLUE Iris Sensitivity Iris Manual VPL-VW50 <Table 2> Lower byte Data Full Normal Wide Zoom Zoom Full1 Full2...
Page 12
NVM Data ERROR STANBY START UP STARTUP LAMP POWER ON COOLING1 COOLING2 SAVING COOLING1 SAVING COOLING2 SAVING STABY USE TIME Refer to Table4 ----- Refer to Table5 ----- <Table 2> Remarks Data Upper byte Lower byte Get only 0000h-FFFFh Set only VPL-VW50...
Page 13
Other Comm Error Waiting time for the return value is about 200 msec. This waiting time for the return value is subject to the conditions that commu- nication is not bothered by any reasons. VPL-VW50 <Table 3> Data Upper byte...
Page 15
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.