5-3. VIDEO SECTION ADJUSTMENTS
When performing adjustments, refer to the layout diagrams
for adjustment related parts beginning from page 5-52.
NTSC model : DCR-TRV5
PAL model :
DCR-TRV5E
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1.
Equipment Required
1) TV monitor
2) Oscilloscope (dual-phenomenon, band above 30 MHz with
delay mode) (Unless specified otherwise, use a 10 : 1 probe.)
3) Frequency counter
4) Digital voltmeter
5)
Audio generator
6)
Audio level meter
7)
Audio distortion meter
8)
Audio attenuator
9)
Regulated power supply
10) Alignment tapes
• Tracking standard (XH2-1)
Parts code: 8-967-997-01
• SW/OL standard (XH2-3)
Parts code: 8-967-997-11
• Audio operation check for NTSC (XH5-3)
Parts code: 8-967-997-51
• System operation check for NTSC (XH5-5)
Parts code: 8-967-997-61
• BIST check for NTSC (XH5-6)
Parts code: 8-967-997-71
• Audio operation check for PAL (XH5-3P)
Parts code: 8-967-997-55
• System operation check for PAL (XH5-5P)
Parts code: 8-967-997-66
• BIST check for PAL (XH5-6P)
Parts code: 8-967-997-76
11) Adjustment remote commander (J-6082-053-B)
12) CPC-8 jig (J-6082-388-A)
13) IR receiver jig (J-6082-383-A)
14) Extension cable (80P, 0.4 mm)
For extension between the DD-110 board (CN802) and the VC-
207 board (CN010) (J-6082-395-A)
15) Power code (J-6082-223-A)
Note: Connect the adjustment remote commander to the LANC jack,
and set the HOLD switch to the "ADJ" side.
5-30