5. Flange Back Adjustment
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
5-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 230 ± 30 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
24 to 29, 38 to 3C
Adjusting method:
1) Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
2) Select page: 6, address: 00, and set data: 01.
3) Check that the data of page: F, address: 24 to 29, 38 to 3C is
the initial value (See table below).
Address
Data
24
4A
25
15
26
90
27
19
28
84
29
13
4) Select page: 6, address: 02, and check that the data is "00".
5) Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
6) Select page: 6, address: 01, set data: 15, and press the PAUSE
button of the adjustment remote commander.
( The adjustment data will be automatically input to page: F,
addresses: 24 to 29, 38 to 3C.)
7) Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1) Turn OFF the main power supply (8.4V).
2) Perform "Flange Adjustment (2)".
Address
Data
38
20
39
00
3A
19
3B
00
3C
1D
5-2. Flange Back Adjustment (2)
Perform this adjustment after performing "Flange Back Adjustment
(1)".
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Adjusting method:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500 m away should
not be in the screen.)
2) Select page: 6, address: 00, and set data: 01.
3) Select page: 6, address: 02, and check that the data is "00".
4) Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
5) Place a ND filter on the lens so that the optimum image is
obtain.
6) Select page: 6, address: 01, set data: 29, and press the PAUSE
button of the adjustment remote commander.
(The adjustment data will be automatically input to page: F,
addresses: 24 to 29, 38 to 3C.)
7) Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments:
1) Select page: 6, address: 00, and set data: 00.
2) Turn OFF the main power supply (8.4V).
3) Perform "Flange Back Check".
5-10
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Check operation on TV monitor
F
24 to 29, 38 to 3C