hit counter script

Initialization Of F; Initializing The F; Modification Of F; F Page Table - Sony DCR-TRV5 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV5:
Table of Contents

Advertisement

1-2. INITIALIZATION OF F PAGE DATA
1. Initializing the F Page Data
Note: If the F Page data has been initialized, "Modification of F Page
Data" and the camera system adjustments need to be performed
again.
Adjusting page
F
Adjusting Address
10 to FF
Initializing Method:
1)
Select page: 6, address: 00, and set data: 01.
2)
Select page: 6, address: 01, set data: 2D (NTSC) or data: 2F
(PAL) and press the PAUSE button of the adjustment remote
commander.
3)
Select page: 6, address: 03, set data: 01, and press the PAUSE
button of the adjustment remote commander.
4)
Wait for more than 2 seconds, and select page: 6, address: 02,
and check that the data is "01".
5)
Perform "Modification of F Page Data".
2. Modification of F Page Data
If the F Page data has been initialized, change the data of the "Fixed
data-2" address shown in the following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 6, address: 00, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5)
After changing the data, select page: 6, address: 00, and set
data: 00.

3. F Page Table

Note: Fixed data-1 : Initialized data. (Refer to "1. Initializing the F Page
Data".)
Fixed data-2 :Modified data. (Refer to "2. Modification of F Page
Data").
Initial value
Address
NTSC
PAL
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
A9
A9
1D
1E
80
80
1F
80
80
20
B4
B4
21
55
55
22
86
86
23
7B
7B
24
4A
4A
25
15
15
26
90
90
27
19
19
28
84
84
29
13
13
2A
2B
2C
40
40
2D
2E
36
36
2F
30
3F
3F
31
32
33
34
89
89
35
59
59
36
38
38
37
41
41
38
20
20
39
00
00
3A
19
19
3B
00
00
3C
1D
1D
3D
3E
3F
40
5-5
Remark
Fixed data-1
(Initialized data)
Fixed data-2
36MHz origin osc adj.
Fixed data-1
HALL adj.
AWB standard data input
Frange back adj.
Fixed data-1
Max gain adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
(Initialized data)
Auto white balance adj.
IRIS IN/OUT adj.
Frange back adj.
Fixed data-1
(Initialized data)

Advertisement