1-1-2. Preparations
Note 1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note 2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1) Connect the equipment for adjustments according to Fig. 5-1-
3.
Note 3: As removing CN006 (2P, 1.0mm) of VC-207 board means
removing the lithium 3V power supply (LI-65 board BT001) ,
data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If CN006 has been
removed, the self-diagnosis data, data on history of use (total drum
rotation time etc. ) will be lost. Before removing, note down the
self-diagnosis data and the data on history use (data of page: 2,
address: 35 to 3D). (Refer to the "Service Mode" for the data on
the history use.)
Note 4: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the power switch block (PS block) removed. After
completing adjustments, be sure to exit the "Forced Camera Power
ON Mode".
Note 5: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Pattern box
Front of the lens
5-2
1.5m
Fig. 5-1-2.