10. MAX GAIN Adjustment

Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note)
Adjustment Page
F
Adjustment Address
2C
Specified Value
70 to 78 (NTSC)
6C to 74 (PAL)
Note: The right two digits of the display data at the right bottom side of
the LCD and TV monitor is the object data.
CA 00 00XX
Switch setting:
1) STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, and set data: 12, and press the
PAUSE button of the adjustment remote commander.
3) Select page: 6, address: 00, and set data: 01.
4) Select page: 6, address: 04, and set data: 01.
5) Select page: 6, address: 40, and set data: 02.
6) Select page: 6, address: 56, and set data: 40.
7) Select page: 6, address: 01, set data: 19 and press the PAUSE
button of the adjustment remote commander.
8) Select page: F, address: 2C, change the data and adjust the DDS
display data (Note) to the specified value.
9) Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1) Select page: D, address: 11, and set data: 10, and press the
PAUSE button of the adjustment remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 6, address: 00, and set data: 00.
4) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
5) Select page: 6, address: 04, and set data: 00.
6)
Select page: 6, address: 40, and set data: 00.
7) Select page: 6, address: 56, and set data: 00.
Object data

11. Auto White Balance Standard Data Input

Subject
Adjustment Page
Adjustment Address
Note 1: Perform "Color Reproduction Adjustment" before this adjustment.
Note 2: Check that the data of page: 6, address: 02 is 00. If not, turn the
power of the unit OFF/ON.
Adjusting method:
1) Select page: 6, address: 00, and set data: 01.
2) Wait for 2 seconds.
3) Select page: 6, address: 01, and set data: 11, and press the
PAUSE button of the adjustment remote commander.
4) Select page: 6, address: 01, and set data: 0D, and press the
PAUSE button of the adjustment remote commander.
(When the standard data is take in, the data will be automatically
input to page: F, address: 20 to 23.)
5) Select page: 6, address: 02, and check that the data is "01".
6) Perform "Auto White Balance Adjustment".
Processing after Completing Adjustments:
1) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2) Select page: 6, address: 00, and set data: 00.
5-14
Clear chart
(Color bar standard picture frame)
F
20 to 23