4.
SELF-DIAGNOSIS CODE TABLE
Self-diagnosis Code
Block
Detailed
Function
Code
C
2
1
0
0
C
2
2
0
0
C
2
3
0
0
C
3
1
1
0
C
3
1
1
1
C
3
1
2
0
C
3
1
2
1
C
3
1
2
2
C
3
1
2
3
C
3
1
2
4
C
3
1
3
0
C
3
1
4
0
C
3
1
4
2
C
3
1
1
0
C
3
1
1
1
C
3
2
2
0
C
3
2
2
1
C
3
2
2
2
C
3
2
2
3
C
3
2
2
4
C
3
2
3
0
C
3
2
4
0
C
3
2
4
2
E
6
1
0
0
E
6
1
1
0
E
6
2
0
0
E
6
2
0
1
Symptom/State
Condensation.
Video head is dirty.
Non-standard battery is used.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
Winding S reel fault when counting the
rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
Winding S reel fault when counting the
rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum
FG fault during normal drum
operations
Difficult to adjust focus
(Cannot initialize focus.)
Zoom operations fault
(Cannot initialize zoom lens.)
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Use the info LITHIUM battery.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Inspect the lens block focus reset sensor (Pin @¡ of CN302 of CD-
193 board) when focusing is performed when the control dial is
rotated in the focus manual mode, and the focus motor drive circuit
(IC303, 304 of VC-207 board) when the focusing is not performed.
Inspect the lens block zoom reset sensor (Pin 7 of CN302 of CD-
193 board) when zooming is performed when the zoom lens is
operated and the zoom motor drive circuit (IC303, 304 of VC-207
board) when zooming is not performed.
Inspect pitch angular velocity sensor (SE301 of CD-193 board)
peripheral circuits.
Inspect yaw angular velocity sensor (SE302 of CD-193 board)
peripheral circuits.
— 8 —
Correction